Regency IG34 Gas Inbuilt Fireplace
INSTALLATION
Mantel Clearances 
Note:  A non-combustible mantel may be 
installed at a lower height if the fram-
ing is made of metal studs covered 
with a non-combustible board.
CLEARANCES TO 
COMBUSTIBLES
Minimum Clearances to Combustibles
                             From Unit             
Sides
 
A 
10" / 255mm
Ceiling 
B 
47.5" / 1205mm
Mantel 
C          13" / 330mm
Max. Mantle Depth 
12" / 305mm 
 
 
(see Dia. 2)
Min. Alcove Width 
F 
48" / 1220 mm
Max. Alcove Depth 
G 
36" / 915 mm
*No  hearth required.
GAS CONNECTION 
GAS CONNECTION WARNING:
Only persons licensed to work 
with gas piping may make the 
necessary gas connections 
to this appliance.  
1)  If the appliance is to be installed into an 
existing chimney system, thoroughly clean 
the masonry fi replace.
2)  The appliance is provided with an opening 
on the right hand side of the control 
compartment. The 9.5mm (3/8") fl exible 
gas hose provided needs to be brought in 
from behind this opening.  Ensure all gas 
connections are tight.
3)  Locate the center point where the vent 
will pass through the chimney above the 
appliance.  Move the appliance into the 
exact location where it is to be installed.  
Ensure that the Insert is level.
CL
Gas
Inlet
FLUEING
This appliance is designed to be attached to 
two 3" (76mm) co-linear aluminium fl ex running 
the full length of the chimney. The fl ue  length 
must be a minimum length of 8 '  (2.44m) and 
a maximum of 35' (10.7m). See chart below for 
minimum distances from roof. Periodically check 
that the vent is unrestricted.
Masonry chimneys may take various contours 
which the fl exible liner will accommodate. 
However, keep the fl exible liner as straight as 
possible
, avoid unnecessary bending.
The Air Intake pipe must  be attached to the inlet 
air collar of the termination cap.
Part # 
Description
948-305 
76mm Flex - 10.6m
46dva-gk Simpson 
Duravent 
Adaptor
46dva-vch  Simpson Vertical high wind cap
MINIMUM FIREPLACE 
DIMENSIONS
The minimum fi replace dimensions for the 
Regency gas space heater are shown in the 
following diagrams:
THE APPLIANCE MUST NOT 
BE CONNECTED TO A
CHIMNEY FLUE SERVING A 
SEPARATE SOLID FUEL
BURNING APPLIANCE AND 
MUST BE TERMINATED TO 
THE OUTDOORS.
Note:    When installing the fl ueing, identify    
         the fl ues.  
            Mark one exhaust and one intake as    
        indicated on the top of the unit.