Measure Rod
The program will display the TPS 1000 "Measure &
Record"dialog or the dialog shown below.
If the difference of the given and measured spacing
between the reflectors exceeds the "Meas. Tol. limit" a
message is displayed.
You may accept the measurement or re-measure the
reflector.
HDNPT\ MEASURE PRISM 1
14:03
MC
Point no.
:
Station12
Hz
:
16°55'50"
V
:
91°16'20"
Slope Dist.
:
-----
m
Height diff
:
-----
m
 ALL
DIST
 REC
TARGT
F1
F2
F3
F4
F5
F6
HELP
CONF
I<>II
Simultaneously measure and record in the active file.
Proceed with the same dialog for the next reflector. If
the last point has already been measured, the program
will proceed  to the "RESULT" dialog.
Measure a distance. Record the measurement in the
active file and proceed with the same dialog for the next
reflector. If the last point has already been measured,
the program will proceed  to the "RESULT" dialog.
Measure the distance. Accept the measurement without
recording. Proceed with the same dialog for the next
reflector. If the last point has already been measured,
the program will proceed  to the "RESULT" dialog.
The prism constant used in the program is shown in the
distance measurement display during the distance
measurement. The prism name also shown in this
display has nothing to do with the prism constant and
can be ignored.