Leica 1000Z01 Manuel D’Utilisation

Page de 347
© Leica
TPS-System 1000 Programs-2.3.1en
115
IV
EL
AH
OH
BS
SM
AS
FS
BL
HB
HP
Enter the target data. For further information refer to
chapter "Measure & Record" of "SYSTEM" - user
manual.
Choosing another reflector and therefore another prism
constant via this function is NOT recommended
because the actually selected prism constant is only
used for the current measurement. After confirming/
storing a measurement with 
 / "REC" or "ALL" the
prism constant set in the program configuration is
automatically used again. This could result in errors.
Therefore always set the prism constant of the pole in
the configuration of the program. Refer to pages 112
and 113.
Change the theodolite face.
Call up the CODE function, input of a code block.
Point no.
: The Point number.
Hz
: Horizontal direction to the hidden
point.
Results
Once all reflectors have been measured, the program
will display the results of the hidden-point calculation.
If 3 reflectors are used, the hidden point position
obtained from the median value of the 3 combinations is
displayed.
HDNPT\   RESULTS
14:03
Northing
:
12145.281
m
Elevation
:
306.005
m
MC
Point no.
:
Station12
Hz
:
16°55'50"
V
:
91°16'20"
Slope Dist.
:
3.345
m
Height diff
:
-0.435
m
Easting
:
2253.635
m
 NEW
 REC
TARGT
F1
F2
F3
F4
F5
F6
HELP