Impinger I -–1000 Series Service Manual - Domestic 
22 
Flame Sensor 
(There should be a visible pilot flame at this time.) 
To check for proper flame sensor operation, 
connect a digital multimeter (capable of measuring 
D. C. microamperes) in series between the flame 
sensor wire (normally connected to terminal #4) 
and terminal #4. NOTE: This is a current 
measurement and the meter must be connected in 
series. This procedure is for checking the pilot 
flame only. Remove main valve wire (Red) from 
terminal #3 on ignition control. With a visible pilot 
flame, the current readings should be as follows: 
Johnson G-65 control, 0.2 micro amp. D.C. 
minimum/Johnson G-60 control, 0.7 micro amp. 
D.C. minimum. If these values are not achieved, 
replace flame sensor. Also check for any type of 
damage to flame sensor wire and connections. 
Pilot flame but no main 
flame
 
Ignition Control and Valve 
Assembly 
If there is a pilot flame, and there is sufficient micro 
amp. current at terminal #4, check for 24 VAC 
that the main valve (internal to valve assembly) has 
opened. Connect a manometer to the manifold gas 
pressure tap located on the back side of the ignition 
control and valve assembly. If no gas is present, 
replace ignition control and valve assembly. 
Centrifugal Switch of Burner 
Blower Motor 
 
 
 
 
 
NOTE: 
Check for 24 VAC output from secondary of 
transformer. If voltage is present, check for 24 VAC 
at terminals marked "24V" and "24V gnd" on 
Ignition Control. If the Burner Blower Motor is 
running and there is no voltage at terminals 24V 
and 24V gnd on the ignition control, replace the 
Burner Blower Motor. 
These Ignition Controls have a 30 second pre-
purge(Delay) and a 15 second lock-out time – The 
Ignition Control will try for ignition for 15 seconds 
and then shut-off. To Re-try for ignition, turn off 
burner switch, wait 30 seconds and re-try ignition. 
For ovens with 
Honeywell ignition 
control
 
Check for 24 VAC supply to ignition control at 
terminals "24V" and "24V gnd". If voltage is 
present, check for 24V at terminal "P.V. (Pilot 
Valve) and "gnd". If voltage is not present, replace 
Ignition Control. If the pilot valve is energized, 
check to see that the high voltage ignitor circuit is 
also energized. To check, disconnect the ignitor 
lead from the ignition control. Place the terminal of 
ignitor lead approximately 1/8" from terminal post 
on Ignition Control. Spark should jump the 1/8" 
gap. If no spark is present, replace ignition control. 
Ignition Control 
If the ignition control is supplied with 24 VAC and 
the pilot valve (in gas valve) and ignitor circuits  
Pilot Shut-off Valve 
If no pilot flame is visible, check to see that the pilot 
shut-off valve is open(shut-off valve is located 
between gas valve and burner). 
Pilot Tube 
Check for gas pressure at pilot tube. Disconnect 
pilot tube at burner and connect manometer to pilot 
tube. If no gas pressure is present, check for 
blockage in pilot tube or pilot shut-off valve. 
Pilot Orifice 
If there is gas pressure at the pilot tube, check the 
pilot orifice for obstructions. Replace as needed. 
No Pilot
 
Burner Ignitor 
Check the burner ignitor head for any obstructions, 
also check for frayed or broken wire, any type of 
damage to spark gap (.100 in. 2.5 mm) If there is 
visible damage, replace ignitor assembly.