Impinger I -–1000 Series Service Manual - Domestic 
23 
 
Pilot flame but no main 
flame 
Spark Ignitor (Flame Sensor) 
(There should be a visible pilot flame at this time). 
NOTE: The Honeywell Ignition Control uses the 
spark ignitor as the flame sensor. If spark 
continues, check for proper ground connections at 
Ignition Control. Check pilot orifice for any partial 
blockage. If the above checks OK, replace ignition 
control. If spark stops when pilot is lit, check for 24 
VAC across M.V. - M.V/ P.V. terminals, if voltage is 
not present, replace ignition control. If voltage is 
present at terminals M.V. - M.V./P.V., the indicator 
light on the control panel should be on, verify that 
the main valve has opened, connect manometer to 
manifold gas pressure tap(located on the  
Temperature Control Valve 
(Robert Shaw) 
Check for gas supply at temperature control. Check 
for temperature control set above 300°F. 
Red Indicator Light is 
on, but no main 
flame
(For ovens with 
mechanical 
thermostat)
 
Main Orifice 
Check for blockage of main orifice. If there is no 
blockage to the main orifice, replace the 
temperature control. 
(For ovens with 
Electronic 
Temperature Control)
 
Temperature Control 
Potentiometer 
Check for 120 VAC across L1 and L2on 
temperature control board. Potentiometer (1000 
ohm,1 turn) WITH POWER OFF: check ohms 
across red and black leads, the ohm reading 
should be 0 to1000 ohms as the dial is turned. 
From green to red, the reading should be 1000 
ohms steady throughout the full turn of the dial. 
NOTE:  Ovens S/N Q18037 and above, the potentiometer is internal to temperature control.  Proceed to next 
component. 
Thermocouple Probe 
Remove thermocouple leads from the temperature 
control board, and measure the millivolt output of 
these leads.  Refer to chart on page 38 in the 
adjustment section for proper readings. 
Temperature Control 
Turn temperature control dial to full "on" position. 
Measure for 120 VAC across terminals "N.O." and 
"L2", if voltage is not present; replace control. 
 
Solenoid Valve 
If voltage is present at terminals "N.O."and "L2", 
check for voltage at solenoid valve. If voltage is 
present, listen for valve to open and close. Also, 
check for opens and shorts in coil. If solenoid valve 
is defective, replace 
Intermittent Heating 
 
Both the main fan motor and burner blower motor 
are equipped with thermo-protection and will cease 
to operate when not cooled properly. This can 
cause the units to cycle on and off intermittently. 
Also, most of the problems listed under "oven will 
not heat" can cause intermittent failures. 
 
For continuing intermittent problems, a series of test lights may be made and installed in 
the ovens. The lights will allow the customer to advise the service technician a trouble code when 
the oven fails. 
 
The lights should be connected in the following manner: 
 
Light#l attached in 120VAC line after Air Pressure Switch.  
Light#2 attached after 120VAC contacts of Burner Motor Relay (or, refer to Bulletin #028 
 for Relay Removal).  
Light#3 in 24VAC Burner Transformer Secondary.  
Light#4 in 24VAC at terminal #6 of Johnson control valve or "24V" on Honeywell Control.  
Light#5 in 24VAC at terminal #1 of Johnson control valve or "PV" on Honeywell Control. 
Light#6 in 24VAC at terminal #3 of Johnson control valve or "MV" on Honeywell Control.  
CODE: 
 
All lights off - lights of main power, main fan off, air pressure switch out.  
1 on 2 off 3 on 4 off 5 off 6 off   
- Burner Motor Relay bad.