Impinger I -–1000 Series Service Manual - Domestic 
TRANSFORMER (12.6 
VAC) 
Upon closure of the Fan Switch, 120 VAC is supplied to the primary of the 12.6 VAC 
Transformer. The Transformer steps the voltage down to 12.6 VAC (normally 13 to 
14 VAC) with a center tap, and supplies power to the Time/ Temp. Display. The 
voltage from each leg of the Transformer's secondary to the center tap should be 
one half of the secondary voltage. 
BURNER CIRCUIT 
Closing the Fan Switch and the normally open Burner Switch supplies 120 VAC 
through the Air Pressure Switch, to the Temperature Control Board, the normally 
open contacts of the Burner Motor Relay (Burner Motor Relay discontinued after S/N 
14791) and the primary of the 24 VAC Transformer. The transformer's secondary 
supplies 24 VAC to the burner motor relay coil (the normally open contacts close 
within 30 seconds), and the normally open Centrifugal Switch. When the relay 
contacts close, the Burner Blower Motor is energized. As this motor reaches approx. 
1,600 R.P.M its internal centrifugal switch closes, supplying 24 VAC to the Gas 
Control Valve. When the Gas Control Valve is supplied with 24 VAC, the pilot valve 
is energized, and the igniter circuit is energized. Ignition should now occur. After pilot 
flame is proven, the Main Gas Valve is energized. The Burner Indicator Light is also 
energized. 
TEMPERATURE 
CONTROL 
Closing the Fan Switch and Burner Switch supplies 120 VAC to the Temperature 
Control Board. The 1K or 1000 ohm Temperature Potentiometer is adjusted to 
desired temperature. The Thermocouple will provide varying millivolts to the 
Temperature Controller. The Temperature Controller supplies 120 VAC to the 
Solenoid Valve at intermittent intervals to maintain desired temperature. 
CONVEYOR DRIVE 
(S/N Q14790 & Below, 
1200 series  
S/N Q14973 & Below 
1000 series) 
 
(S/N Q14791 & Above, 
1200 series refer to Pg. 
5 & 6 S/N Q14974 & 
Above, 1000 series refer 
to Pg. 5 & 6 (STEPPER) 
Closing the fan switch and the normally open conveyor Switch supplies 120 VAC to 
the Motor Control Board. AC volts are converted to DC volts and are supplied to the 
Conveyor Motor, at terminals A+ and A-. Adjustment of the Speed Control 
Potentiometer (5,000 ohm 10 turn) will change resistance at terminals P1, P2, and 
P3 varying the DC voltage to the Conveyor Motor. The speed of the conveyor motor 
will increase or decrease as the DC voltage from the board increases or decreases 
respectively. As the motor turns, it drives both the reducer gearbox and the tach. 
generator. The tach. Generator is a DC voltage generator, which supplies a voltage 
to the DC motor control board and is used as a reference for maintaining a constant 
conveyor speed. 
NOTE: 
The 1200 Series Ovens utilize 2 complete conveyor drive systems. 
TIME/TEMP 
DISPLAY(S/N Q14790 & 
Below, 1200 series  
S/N Q14973 & Below 
1000 series) 
 
(S/N Q14791 & Above, 
1200 series refer to Pg. 
5 & 6 S/N Q14974 & 
Above, 1000 series refer 
to Pg. 5 & 6 (STEPPER) 
The Time/Temp. Display is energized when the Fan Switch is closed, supplying 120 
VAC to the primary of the12.6 volt Transformer. The secondary output of the 
transformer, normally 13 to 14 VAC (depending on input), with a center tap, is 
supplied to terminals 1,2, and 3 of the Time/Temp. Display. The center tap is 
terminal 2. The display works on a balanced input and center tap voltage to each leg 
must be 1/2 the total reading. 
The speed side of the Time/Temp. Display uses a slotted disc (cemented to tach. 
coupling) to break the infrared light beam of the optical switch (mounted on gear 
motor) producing electrical pulses that are transmitted to the display. The display 
converts these pulses into a read-out of minutes and seconds. The temperature 
portion of the display uses a Thermistor Probe to sense oven temperature. The 
thermistor outputs a resistance proportional to the oven temperature. This resistance 
is then converted by the display into a temperature reading. 
NOTE* 
The 1200 Series Ovens use a Double Pole Double Throw Switch to connect the two 
Optical Encoder Assemblies to the Time/Temp. Display. By activating the switch, 
either the front or rear belt speed can be shown by the Time/Temp Display . 
CONVEYOR DRIVE 
Closing the Oven Fan Switch supplies 120 VAC, through the Power Transformer, to 
the normally open Conveyor Switch. Closing the Conveyor Switch supplies 120 VAC, 
through a 3 AMP Fuse, to the primary of the Conveyor Control Transformer. The 
secondary of this Transformer supplies 10 VAC and 29 VAC to the Conveyor 
Control. The conveyor control supplies voltage pulses to the Conveyor Control. The 
Conveyor Control Potentiometer varies the frequency of these pulses. The motor 
speed will increase or decrease, as the frequency of the pulses increase or decrease 
respectively.