Impinger I -–1000 Series Service Manual - Domestic 
generator. The tach. generator is a DC voltage generator which supplies a voltage to 
the  DC  motor  control  board  and  is  used  as  a  reference  for maintaining  a  constant 
conveyor speed. 
NOTE 
The 1200 Series Ovens utilize 2 complete conveyor drive systems. 
TIME TEMP DISPLAY 
The Time/Temp. Display is energized when the Fan Switch is closed, supplying120 
VAC to the primary of the 12.6 volt Transformer The secondary output of the 
transformer, normally 13 to 14 VAC (depending on input), with a center tap is 
supplied at terminals 1,2, and 3 of the Time/Temp. Display. The center tap is 
terminal 2. The display works on a balanced input and center tap voltage to each leg 
must be 1/2 the total reading. 
 
The speed side of the Time/Temp. Display uses a slotted disc (cemented to tach. 
coupling) to break the infra-red light beam of the optical switch (mounted on gear 
motor) producing electrical pulses that are transmitted to the display. The display 
converts these pulses into a read-out of minutes and seconds. The temperature 
portion of the display uses a Thermistor Probe to sense oven temperature. The 
thermistor outputs a resistance proportional to the oven temperature. This resistance 
is then converted by the display into a temperature reading. 
NOTE:
 The 1200 Series Ovens use a Double Pole Double Throw Switch to connect 
the  two  Optical  Encoder  Assemblies  to  the  Time/Temp  Display.  By  activating  the 
switch, either the front or rear belt speed can be shown by the Time/Temp Display. 
SEQUENCE OF OPERATIONS 1022 / 1023 / 1202 / 1203 
 
MODEL 1022 - 120/208 VAC - 3 PHASE 
MODEL 1023 - 120/240 VAC - 3 PHASE 
MODEL 1202 - 120/208 VAC - 3 PHASE - DUAL BELT 
MODEL 1203 - 120/240 VAC - 3 PHASE - DUAL BELT 
 
POWER SUPPLY 
Electrical Power to be supplied to the Oven by a five conductor service. Voltage from 
the black conductor to the white conductor is 120 VAC. 
Black conductor is Hot 
Red conductor is Hot 
Orange conductor is Hot 
White conductor is Dedicated Neutral 
Green conductor is Ground 
 
MAIN FAN CIRCUIT 
Electrical power is permanently supplied through 6, 50A fuses to the normally open 
contacts of the Mercury Contactors. Power is also supplied through 2, 15A fuses to 
the normally open contacts of the Double Pole Main Fan Relay, the Double Pole 
Main Fan Switch, and the normally open Cool-Down Thermostat (thermostat closes 
at 160°F and opens at 140°F.) Closing the Main Fan Switch energizes the coil of the 
Main Fan Relay. The normally open contacts now close, energizing the Main Fan 
Motor, and the Control Box Cooling Fan. Closing the Fan Switch also supplies power 
to the Hour Meter (hour meter discontinued after S/N 3484), the 12.6 VAC 
Transformer, the Heat and Conveyor Switches. 
TRANSFORMER (12.6 
VAC) 
Upon closure of the Fan Switch, 120 VAC is supplied to the primary of the 12.6 VAC 
Transformer. The Transformer steps the voltage down to 12.6 VAC (normally 13 to 
14 VAC) with a center tap, and supplies power to the Time/Temp Display. The 
voltage from each leg of the Transformer's secondary to the center tap should be 
one half of the secondary voltage. 
HEAT CIRCUIT 
Closing the Fan Switch and the normally open Heat Switch supplies 120 VAC 
through the Air Pressure Switch and the normally closed Hi-Limit Thermostat 
(manually re-settable, opens at 190°F) the 3A Fuse, to the L1 terminal of the 
Temperature Control Board, the coils of the Mercury Contactors, and to the Heat 
Indicator Light. 
TEMPERATURE 
CONTROL 
When the Heat Switch is closed, 120 VAC is supplied to the Temperature Control. 
The Temperature Control Potentiometer (2.5K ohm) is adjusted to desired 
temperature. The Thermocouple will provide varying millivolts to the Temperature 
Controller. The Temperature Controller switches the L2 line of the Contactor coils at 
intermittent intervals to maintain desired temperature.