Hoshizaki KM-901MAH Manuel D’Utilisation

Page de 87
66
Problem
Possible Cause
Remedy
[] Freeze cycle time is 
long. (continued)
n) Control Board
. Float switch 
connection loose (K5).
. Check and reconnect.
. Defective.
. See "IV.B. Control Board 
Check." 
[] Harvest cycle time is 
long.
a) Water Supply
. Water temperature too 
cold.
. Increase temperature.
b) Thermistor
. Disconnected, loose, 
or defective.
. Connect, secure, check. 
See "V.L. Removal 
and Replacement of 
Thermistor" and "IV.E. 
Thermistor Check."
c) Control Board
. Not reading 
thermistor.
. Check and replace. See 
"IV.E. Thermistor Check."
. Sending voltage to 
liquid line valve (if 
applicable) in harvest.
. Check and replace. See 
"IV.B. Control Board 
Check." 
d) Inlet Water Valve
. Clogged.
. Clean or replace.
e) Evaporator
. Scaled up.
. Clean.
. Damaged.
. Replace.
f) Hot Gas Valve 
. Does not open, or 
opens partially.
. Check and replace.
g) Expansion Valve
. Wide open in harvest. . Check and replace.
. Bulb loose.
. Secure bulb.
h) Water Regulating Valve 
(water-cooled model)
. Open during harvest. . Adjust or replace. See 
"V.J. Adjustment of Water 
Regulating Valve."
i) Liquid Line Valve (if 
applicable)
. Open during harvest 
cycle.
. Check and replace.
4. Abnormal Ice
Problem
Possible Cause
Remedy
[] Small cubes.
a) Pump-Out Check Valve . Dirty or worn and 
leaking by.
. Clean or replace.
b) Ice Cube Guide
. Out of position. 
Circulated water falls 
into bin.
. Place in position.
c) Water System
. Water supply line too 
small; requires 3/8" 
OD line dedicated per 
machine.
. Increase water line size.
. Water filter clogged or 
flow rate too small.
. Replace filter or install a 
higher flow rate filter.
d) Inlet Water Valve
. Dirty mesh filter or 
orifice.
. Clean.
e) Pump Motor
. RPM too slow.
. See chart .[5].
f) Control Board
. Defective.
. See "IV.B. Control Board 
Check."