Hoshizaki KM-901MAH Manuel D’Utilisation
66
Problem
Possible Cause
Remedy
[] Freeze cycle time is
long. (continued)
n) Control Board
. Float switch
connection loose (K5).
. Check and reconnect.
. Defective.
. See "IV.B. Control Board
Check."
[] Harvest cycle time is
long.
a) Water Supply
. Water temperature too
cold.
. Increase temperature.
b) Thermistor
. Disconnected, loose,
or defective.
. Connect, secure, check.
See "V.L. Removal
and Replacement of
Thermistor" and "IV.E.
Thermistor Check."
and Replacement of
Thermistor" and "IV.E.
Thermistor Check."
c) Control Board
. Not reading
thermistor.
. Check and replace. See
"IV.E. Thermistor Check."
. Sending voltage to
liquid line valve (if
applicable) in harvest.
applicable) in harvest.
. Check and replace. See
"IV.B. Control Board
Check."
Check."
d) Inlet Water Valve
. Clogged.
. Clean or replace.
e) Evaporator
. Scaled up.
. Clean.
. Damaged.
. Replace.
f) Hot Gas Valve
. Does not open, or
opens partially.
. Check and replace.
g) Expansion Valve
. Wide open in harvest. . Check and replace.
. Bulb loose.
. Bulb loose.
. Secure bulb.
h) Water Regulating Valve
(water-cooled model)
. Open during harvest. . Adjust or replace. See
"V.J. Adjustment of Water
Regulating Valve."
Regulating Valve."
i) Liquid Line Valve (if
applicable)
. Open during harvest
cycle.
. Check and replace.
4. Abnormal Ice
Problem
Possible Cause
Remedy
[] Small cubes.
a) Pump-Out Check Valve . Dirty or worn and
leaking by.
. Clean or replace.
b) Ice Cube Guide
. Out of position.
Circulated water falls
into bin.
into bin.
. Place in position.
c) Water System
. Water supply line too
small; requires 3/8"
OD line dedicated per
machine.
OD line dedicated per
machine.
. Increase water line size.
. Water filter clogged or
flow rate too small.
. Replace filter or install a
higher flow rate filter.
d) Inlet Water Valve
. Dirty mesh filter or
orifice.
. Clean.
e) Pump Motor
. RPM too slow.
. See chart .[5].
f) Control Board
. Defective.
. See "IV.B. Control Board
Check."