Adtran MX410 Manuel D’Utilisation

Page de 108
Rear Panel
MX410/MX412 System Manual
4-4
PRELIMINARY
61189500L1-1B
Alarm Contacts/AUX Inputs
The alarm contacts and auxiliary (AUX) inputs are shown in 
Figure 4-4.  Alarm Contacts and AUX Inputs
The alarm interfaces connect to the nine Form C type relays on the MX410/MX412 labeled 
CRIT
,
 
 
MAJOR
, and 
MINOR
. Both NC (Normally Closed) and NO (Normally Open) contacts are 
provided. Connect the 
CRIT 
(Critical), 
MAJOR
, and 
MINOR
 alarm leads from the fuse and alarm 
panel to the 
C
 (Common) and 
NO
 or 
NC
 wire-wrap terminals on the MX410/MX412 rear panel 
as required.
Auxiliary alarms 1-4 connect to the MX410/MX412 
AUX INPUTS
 labeled 
1
-
9
. These pins detect 
open and closed relay contacts and are not polarity sensitive. 
 shows the pin assign-
ments for the 
AUX INPUTS
.
The alarm severity level can be changed in the Environmental Alarms menu. 
After the alarm contact and AUX input connections have been made, install the protective 
cover over the wire-wrap headers.
Table 4-1.  AUX Inputs 1-9 Pin List
AUX INPUT
Function
Default Severity Level
1, 2
Alarm 1 
Critical
3, 4
Alarm 2
Major
5, 6
Alarm 3
Minor
7, 8
Alarm 4
Alert
9
No Connect
N/A