PELLET VENT MUST MAINTAIN A MINIMUM 3” CLEARANCE TO ANY COMBUSTIBLE (INSTALL 
VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER).  
 
DO NOT CONNECT THE PELLET VENT TO A VENT SERVING ANY OTHER APPLIANCE OR STOVE.  
 
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.  
 
 
Figure 28 
These examples show two styles of vertical install.
  These require Spacer Kit # ACI-3VL.   
The framed openings for these installations need to be: 
                Tradition         Bay View 
Height       21” 
 
21 - 25” 
Width        30” 
 
30” 
Depth        17” 
 
17” 
 
If constructing a chase, adequate, insulation, vapor barrier, drywall, and caulking  must be used. 
18”
8”
6”
Wall Band / 
Support Brkt
every 5’
Wood Frame
Construction
Ceiling Support /
Firestop Spacer
Stand Off 
Part ACISOVL
3” minimum
    air gap
Vertical Vent Installation
18”
8”
6”
Wall Band / 
Support Brkt
every 5’
Wood Frame
Construction
Ceiling Support /
Firestop Spacer
Stand Off 
Part ACISOVL
3” minimum
    air gap
Vertical Vent Installation
Interior
Chase
2’
Metal
Chase Cap
Storm Collar
Rain Cap
Clean Out Tee
Clean Out Tee
10’
2’
Shroud
Wood Surround
Wood Surround
Shroud