Rotel RC-1082 Manuel Complémentaire

Page de 1
RC 1082 
RS232 Controller Command List 
 
Table: RC 1082 Waveform format expected: 
 
Baud Rate 
Parity 
Valid Data Bits 
Stop Bit Value 
Handshaking 
Data Type 
19200 N 
None 
String 
 
Table: RC 1082 expected format of a request by RS232 controller: 
 
Start Count Device 
ID Type Key Checksum 
0xFE 0x03 
0x06  0x10 
0xXX  0xXX 
 
Table 1: Command List 
 
NOTE: The values in the table below show the exact byte sequence of all requests.  The device 
will expect the bytes only - no spaces, no delimiter, etc.  The controlling device may implement its 
own method to download each command sequence.  The numerical values in the first column are 
Hexadecimal.  
 
RC 1082 HEX 
Command 
Command Description 
FE 03 06 10 00 19 
Power Power 
Toggle 
FE 03 06 10 01 1A 
Power Off 
Power Off 
FE 03 06 10 02 1B 
Power On 
Power On 
FE 03 06 10 03 1C 
Phono Listen 
Phono 
FE 03 06 10 04 1D 
CD Listen 
CD 
FE 03 06 10 05 1E 
Tuner Listen 
Tuner 
FE 03 06 10 06 1F 
Aux 1 
Listen Aux 1 
FE 03 06 10 07 20 
Aux 2 
Listen Aux 2 
FE 03 06 10 08 21 
Aux 3 
Listen Aux 3 
FE 03 06 10 09 22 
Tape 1 
Listen Tape 1 
FE 03 06 10 0A 23 
Tape 2 
Listen Tape 2 
FE 03 06 10 0B 24 
Record Phono 
Record Phono 
FE 03 06 10 0C 25 
Record CD 
Record CD 
FE 03 06 10 0D 26 
Record Tuner 
Record Tuner 
FE 03 06 10 0E 27 
Record Aux 1 
Record Aux 1 
FE 03 06 10 0F 28 
Record Aux 2 
Record Aux 2 
FE 03 06 10 10 29 
Record Aux 3 
Record Aux 3 
FE 03 06 10 11 2A 
Record Tape 1 
Record Tape 1 
FE 03 06 10 12 2B 
Record Off 
Record Off 
FE 03 06 10 13 2C 
Vol+ Volume 
Up 
FE 03 06 10 14 2D 
Vol- Volume 
Down 
FE 03 06 10 15 2E 
Mute Mute 
Toggle 
FE 03 06 10 1A 33 
Record Function 
Record Function Select