EPIM-C
CyberSWITCH CSX400 and CSX400-DC Installation Guide
A-5
EPIM-C
The EPIM-C supports thin coaxial cabling and is equipped with an internal Cabletron Systems
TMS-3 Transceiver. You can use the TERM switch on the front of the EPIM-C to set the internal
50-ohm terminator. This eliminates the need to connect the port to a T-connector and terminator.
TMS-3 Transceiver. You can use the TERM switch on the front of the EPIM-C to set the internal
50-ohm terminator. This eliminates the need to connect the port to a T-connector and terminator.
shows the setting for the terminator switch.
Figure A-4
EPIM-C
Connector Type
This connector type is a BNC receptacle with gold center contact for use with BNC type
T-connectors and RG58 coaxial cable.
T-connectors and RG58 coaxial cable.
Grounding
The BNC port of the Coaxial Interface Modules is not connected to earth ground.
!
CAUTION
For safety reasons, only one end of a coaxial segment should be connected to earth
ground. Connection to earth ground at more than one point on the segment may
cause dangerous ground currents.
ground. Connection to earth ground at more than one point on the segment may
cause dangerous ground currents.