These operating irregularities do not have error messages. 
Error Possible 
cause 
Remedy 
Suction plate not correctly locked 
Lock suction plate correctly 
Nominal oven temperature too high 
Select lower temperature and increase 
cooking time 
Not pre-heated 
Always pre-heat  
Bypass pipe greasy 
Clean bypass 
Uneven browning 
Incorrect accessories, container 
Use suitable accessories 
Control elements not illuminated and 
do not react when switched on 
No power connection, external failsafe 
triggered 
Call customer service 
Combi does not react to information 
entered 
Software has hung itself up 
Hold down the ON/OFF switch for 5 
seconds or disconnect Combi for 5 
seconds 
Combi cannot be switched on or off 
ON/OFF has been locked for 3 
seconds 
Try again after 3 seconds 
Oven is not lit inside 
Oven light fault 
Call customer service 
Steam measuring line blocked 
Clean steam measurement line; see 
“Daily servicing and maintenance” 
Water sprays from air outlet when door 
is closed 
Combi drain blocked 
Clean outflow 
Water sprayed out of steam generator 
into oven during operation 
Automatic rinsing of steam generators 
has not been carried out for some time, 
i.e. it is continually deselected 
Descale steam generators 
Water inside the oven 
Outflow blocked 
Rinse condenser and outflow 
thoroughly, clean/check own drain 
system 
Outflow connection blocked or covered  Remove object 
Water running out of base of Combi 
Outflow blocked 
Rinse condenser and outflow 
thoroughly, clean/check own drain 
system 
Incorrect cleaning agent 
Use original CONVOClean forte or new 
cleaning agents 
Black marks inside oven 
Water hardness too high 
See Water Quality Recommendations 
in Warranty 
Water pressure too low 
Increase pressure at installation 
location 
Incorrect cleaning agent 
Switch to CONVOClean 
Automatic cleaning (CONVOClean 
system) gives poor cleaning results 
Degree of soiling incorrectly set 
Select higher cleaning level