Cleveland oeb-10.10 Manuel De Montage
30
These operating irregularities do not have error messages.
Error Possible
cause
Remedy
Suction plate not correctly locked
Lock suction plate correctly
Nominal oven temperature too high
Select lower temperature and increase
cooking time
cooking time
Not pre-heated
Always pre-heat
Bypass pipe greasy
Clean bypass
Uneven browning
Incorrect accessories, container
Use suitable accessories
Control elements not illuminated and
do not react when switched on
do not react when switched on
No power connection, external failsafe
triggered
triggered
Call customer service
Combi does not react to information
entered
Software has hung itself up
Hold down the ON/OFF switch for 5
seconds or disconnect Combi for 5
seconds
seconds or disconnect Combi for 5
seconds
Combi cannot be switched on or off
ON/OFF has been locked for 3
seconds
seconds
Try again after 3 seconds
Oven is not lit inside
Oven light fault
Call customer service
Steam measuring line blocked
Clean steam measurement line; see
“Daily servicing and maintenance”
“Daily servicing and maintenance”
Water sprays from air outlet when door
is closed
is closed
Combi drain blocked
Clean outflow
Water sprayed out of steam generator
into oven during operation
into oven during operation
Automatic rinsing of steam generators
has not been carried out for some time,
i.e. it is continually deselected
has not been carried out for some time,
i.e. it is continually deselected
Descale steam generators
Water inside the oven
Outflow blocked
Rinse condenser and outflow
thoroughly, clean/check own drain
system
thoroughly, clean/check own drain
system
Outflow connection blocked or covered Remove object
Water running out of base of Combi
Outflow blocked
Rinse condenser and outflow
thoroughly, clean/check own drain
system
thoroughly, clean/check own drain
system
Incorrect cleaning agent
Use original CONVOClean forte or new
cleaning agents
cleaning agents
Black marks inside oven
Water hardness too high
See Water Quality Recommendations
in Warranty
in Warranty
Water pressure too low
Increase pressure at installation
location
location
Incorrect cleaning agent
Switch to CONVOClean
Automatic cleaning (CONVOClean
system) gives poor cleaning results
system) gives poor cleaning results
Degree of soiling incorrectly set
Select higher cleaning level