Cleveland oeb-6.10 Manuel D’Utilisation

Page de 8
Cleveland
Project  ________________________________
Item  __________________________________
Quantity _______________________________  
FCSI Section  ____________________________
Approval  _______________________________
Date  __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110 
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com  
 
COMBI OVEN-STEAMER 
Stacking Kits for Gas Table Type Models
(OGB 6.10 on OGB 6.10 or OGS 6.10 on OGS 6.10)
SECT.
IIB
PAGE 
5A
0707
by
by
Cleveland
Cleveland
Model #
Description
CSTK-610
for mounting two 6.10 models
CSTK-610CA
for mounting two 6.10 models (with casters)
UNIT A
UNIT B
6.00
"
NOTE: Overall height of unit does not change for units with casters.
7
RC
CS
W1
W2
D
G
4.38"
NOTE: Overall height of unit does not change for units with casters.
RC
CS
W1
W2
D
G
RC
CS
W1
W2
D
G
4.38"
38.08"
39.21"
LEFT SIDE VIEW
6.10
on 6.10
GAS
6
UNIT A
UNIT B
3
36.70"
1.58"
2
8
.4
3
5.00"
1.82"
6
7
.8
5
"
2
8
.4
3
6.00"
7
8
.0
0
(M
IN
.H
O
O
D
R
E
Q
U
IR
E
M
E
N
T
)
2.52"
7
UTILITIES
(Utility connection shown below are listed per unit)
Required Clearances:
Rear - 2", Left Side - 4", Right Side - 2 1/2"
• Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located
next to the unit.
• Allow for sufficient clearance on left side for service access (contact the
factory service department for recommendations).
• Installation must comply with all local fire and health codes.
Electrical Requirements:
120 volt, 60 Hz, single phase, UNIT A - 11.7 amps
Do not connect to a G.F.I. outlet.
UNIT B - 11.7 amps
Gas Connection:
3/4" NPT
Gas Type:
Natural Gas (Propane optional)
Gas Flow Pressure:
Natural Gas - Min. 5.5" WC / Max. 14" WC
Propane Gas - Min. 11" WC / Max. 14" WC
BOILER MODELS
UNIT A - OGB-6.10
UNIT B - OGB-6.10
Total Connected Load:
45.400 BTU
45.400 BTU
Steam Generator:
45.400 BTU
45.400 BTU
Hot Air:
45.400 BTU
45.400 BTU
BOILERLESS MODELS
UNIT A - OGS-6.10
UNIT B - OGS-6.10
Total Connected Load:
45.400 BTU
45.400 BTU
Hot Air:
45.400 BTU
45.400 BTU
W1
W2
D
RC
S
CS
AV
G
E1
E2
W1
W2
D
RC
S
CS
AV
G
E1
E2
Water Connections:
Cold Water (drinking water quality)
Flow Pressure:
30 - 60 PSI
Water Inlets:
3/4" GHT-F (Female Garden Hose Connection)
Treated Water for Steam Generator
Untreated Water for Condenser
Drain Connection:
2" Tube
Venting:
Exhaust Hood required
*Connection for Cleaning Solution
*Connection for Rinse Cycle
*Available as an option
Note: For additional connection details, see spec sheet for each
individual combi model to be stacked.
W1
W2
D
RC
S
CS
AV
G
W1
W2
D
RC
S
CS
AV
G
E1
W1
W2
D
RC
S
CS
AV
G
E1
E2
W1
W2
D
RC
S
CS
AV
G
W1
W2
D
RC
S
CS
AV
G