Cleveland oeb-6.10 Manuel D’Utilisation

Page de 8
Cleveland
Project  ________________________________
Item  __________________________________
Quantity _______________________________  
FCSI Section  ____________________________
Approval  _______________________________
Date  __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110 
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com  
 
COMBI OVEN-STEAMER
Stacking Kits for Electric Table Type Models
(OEB 6.20 on OEB 10.20 or OES 6.20 on OES 10.20)
SECT.
IIB
PAGE 
5H
0707
by
by
Cleveland
Cleveland
Model #
Description
CSTK-1020
for mounting one 6.20 model on top of one 10.20 model
CSTK-1020CA
for mounting one 6.20 model on top of one 10.20 model (with casters)
UNIT A
UNIT B
& CSTK-6.1CA*
36.70"
1.58"
2
8
.4
3
5.00"
1.82"
6
7
.  8
5
"
7
1
.2
4
"
8
0
.0
9
"
7
8
.4
1
"
2
8
.4
3
6.00"
6.10
6.10
2.52"
36.70"
2.52"
1.58"
1.82"
2
8
.4
3
5.00"
3
8
.9
8
"
6.00
"
6.10
10.10
47.92"
2.52"
1.58"
1.82"
CSTK-10.10 & CSTK-10.10CA*
3
0
.1
2
"
5.00
"
3
8
.9
8
"
6.00"
NOTE: Overall height of unit does not change for units with casters.
7
8
.0
0
” 
(M
IN
. H
O
O
D
 R
E
Q
U
IR
E
M
E
N
T
)
8
0
.0
0
” 
(M
IN
. H
O
O
D
 R
E
Q
U
IR
E
M
E
N
T
)
7
8
.0
0
” 
(M
IN
. H
O
O
D
 R
E
Q
U
IR
E
M
E
N
T
)
8
1
.0
0
” 
(M
IN
. H
O
O
D
 R
E
Q
U
IR
E
M
E
N
T
)
RC
CS
W1
W2
D
G
RC
CS
W1
W2
D
RC
CS
W1
W2
D
RC
CS
W1
W2
D
G
4.38"
39.50"
4.38"
48.32"
47.72"
46.34"
NOTE: Overall height of unit does not change for units with casters.
UNIT A
UNIT A
UNIT B
UNIT B
UNIT A
UNIT A
UNIT B
UNIT B
LEFT SIDE VIEW
FRONT VIEW
LEFT SIDE VIEW
FRONT VIEW
7
1
.2
0
"
47.92"
2.52"
1.58"
1.82"
3
0
.1
2
"
5.00
"
3
0
.1
2
"
6.00"
7
8
.0
0
” 
(M
IN
. H
O
O
D
 R
E
Q
U
IR
E
M
E
N
T
)
RC
CS
W1
W2
D
RC
CS
W1
W2
D
4.38"
39.50"
46.34"
NOTE: Overall height of unit does not change for units with casters.
UNIT A
UNIT A
UNIT B
UNIT B
LEFT SIDE VIEW
FRONT VIEW
6.20
on 6.20
GAS
6.20
on 6.20
ELEC
6.20
on 10.20
GAS
6.20
on 10.20
ELEC
8
0
.0
9
"
47.92"
2.52"
1.58"
1.82"
3
0
.1
2
"
5.00
"
3
8
.9
8
"
6.00"
8
1
.0
0
” 
(M
IN
. H
O
O
D
 R
E
Q
U
IR
E
M
E
N
T
)
RC
CS
W1
W2
D
G
RC
CS
W1
W2
D
G
4.38"
48.32"
47.72"
NOTE: Overall height of unit does not change for units with casters.
UNIT A
UNIT A
UNIT B
UNIT B
LEFT SIDE VIEW
FRONT VIEW
NOTE: Overall height of unit does not change for units with casters.
RC
CS
W1
W2
D
G
RC
CS
W1
W2
D
G
4.38"
38.08"
39.21"
LEFT SIDE VIEW
6.10
on 6.10
GAS
6.10
on 10.10
GAS
RC
CS
W1
W2
D
G
RC
CS
W1
W2
D
G
4.38"
48.54”
39.21"
NOTE: Overall height of unit does not change for units with casters.
UNIT A
UNIT B
LEFT SIDE VIEW
UNIT A
UNIT B
37.83"
LEFT SIDE VIEW
36.70"
1.58"
1.82"
2.52"
RC
CS
W1
W2
D
RC
CS
W1
W2
D
NOTE: Overall height of unit does not change for units with casters.
4.38"
38.08"
2
8
.4
3
5.00"
6
7
.  8
5
"
2
8
.4
3
6.00"
7
8
.0
0
” 
(M
IN
. H
O
O
D
 R
E
Q
U
IR
E
M
E
N
T
)
UNIT A
UNIT B
UNIT A
UNIT B
RC
CS
W1
W2
D
RC
CS
W1
W2
D
37.83"
NOTE: Overall height of unit does not change for units with casters.
LEFT SIDE VIEW
UNIT A
UNIT B
4.38"
48.54"
6.10
on 6.10
ELEC
6.10
on 10.10
ELEC
36.70"
1.58"
2
8
.4
3
5.00"
1.82"
6
7
.  8
5
"
2
8
.4
3
6.00"
7
8
.0
0
” 
(M
IN
. H
O
O
D
 R
E
Q
U
IR
E
M
E
N
T
)
2.52"
7
8
.4
1
"
36.70"
1.58"
1.82"
2
8
.4
3
5.00"
3
8
.9
8
"
6.00
"
8
0
.0
0
” 
(M
IN
. H
O
O
D
 R
E
Q
U
IR
E
M
E
N
T
)
2.52"
7
8
.4
1
"
36.70"
1.58"
1.82"
2
8
.4
3
5.00"
3
8
.9
8
"
6.00
"
8
0
.0
0
” 
(M
IN
. H
O
O
D
 R
E
Q
U
IR
E
M
E
N
T
)
2.52"
UTILITIES
(Utility connection shown below are listed per unit)
Required Clearances:
Rear - 2", Left Side - 4", Right Side - 2 1/2"
• Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to 
the unit.
• Allow for sufficient clearance on left side for service access (contact the factory
service department for recommendations).
• Installation must comply with all local fire and health codes.
Electrical Requirements:
Do not connect to a G.F.I. outlet.
BOILER
UNIT A - OEB-6.20
UNIT B - OEB-10.20
MODELS
208/3/60 240/3/60
440/3/60 480/3/60
208/3/60 240/3/60 440/3/60 480/3/60
Total Connected Load: 
16.4 KW  21.6 KW
18.5 KW 22 KW 
26.3 KW 34.9 KW
29.4 KW 34.9 KW
Hot Air: 
14.7 KW
19.6 KW
16.5 KW 19.6 KW
25.8 KW 34.3 KW
28.8 KW 34.3 KW
Steam Generator:
12.8 KW
17.1 KW
14.3 KW 17.1 KW
20.5 KW 27.3 KW
22.9 KW 27.3 KW
Amps per Phase:
45.5
51.8
24.2
26.4
77.8
88.8
41.4
44.9
BOILERLESS
UNIT A - OES-6.20
UNIT B - OES-10.20
MODELS
208/3/60 240/3/60
440/3/60 480/3/60
208/3/60 240/3/60 440/3/60 480/3/60
Total Connected Load:
16.4 KW  21.6 KW
18.5 KW 22 KW
26.3 KW 34.9 KW
29.4 KW 34.9 KW
Hot Air:
14.7 KW
19.6 KW
16.5 KW 19.6 KW
25.8 KW 34.3 KW
28.8 KW 34.3 KW
Amps per Phase:
45.5
51.8
24.2
26.4
77.8
88.8
41.4
44.9
W1
W2
D
RC
S
CS
AV
G
E1
Water Connections:
Cold Water (drinking water quality)
Flow Pressure:
30 - 60 PSI
Water Inlets:
3/4" GHT-F (Female Garden Hose
Connection)
Treated Water for Steam Generator
Untreated Water for Condenser
Drain Connection:
2" Tube
Venting:
Exhaust Hood required
*Connection for Cleaning Solution
*Connection for Rinse Cycle
*Available as an option
Note: For additional connection details, 
see spec sheet for each individual 
combi model to be stacked.
W1
W2
D
RC
S
CS
AV
G
W1
W2
D
RC
S
CS
AV
G
W1
W2
D
RC
S
CS
AV
G
E1
E2
W1
W2
D
RC
S
CS
AV
W1
W2
D
RC
S
CS
AV
G