6. SMART STATUS
6.1. About this chapter
The Smart Status function allows you to view the configuration and the current state
of both instrument and tested interface. On ISDN interface, interaction with the B
channel status is also possible.
of both instrument and tested interface. On ISDN interface, interaction with the B
channel status is also possible.
6.2. Reading the Basic Rate status
1
Displays page 1 of the available information.
Page 1 shows:
►
Instrument configuration
►
Type of test in progress
►
Current test state
►
Filling percentage of the internal buffer for storing monitor events
►
Current date and time
►
State of ISDN layers referred to the OSI model
2
Goes to page 2.
This page displays all B channels with state according to the icons below:
Channel not used.
Activity (in monitor mode) or test in progress (in simulation
mode).
mode).