This indicator lights when the power amplifi er has been switched on. Causes for the 
POWER-indicator not lighting are: the appliance is not connected to the mains 
or the primary fuse is defective. 
The PROTECT LED indicating that one of the internal protection circuits 
against thermal overload, short-circuit, Back-EMF, HF-occurrence at the output, 
etc., has been activated. The output relays interrupt the connected loads from    
 
the power amps while input signals are interrupted as well, preventing the connected  
 
loudspeaker systems and the power amplifi ers themselves from being damaged.
 
Whatever caused the fault – e.g. a short-circuited speaker cable – needs to be reme-
died. In case of thermal overload you have to wait until the power amplifi er automati-
cally regains normal operation.
modulation is present at the output. The LED is dimmed when speaker cables are
short-circuited or a protection circuit has been activated.
The 0dB LED lights whenever the power amplifi er is driven at its maximum. Higher 
nput voltage does not result in higher peak output voltage. In addition, the 0dB
ndicator comes in handy when adjusting external limiters.
This indicator lights as soon as the integrated dynamic audio signal limiter is
activated and the power amplifi er is driven at the clipping limit or generally at its 
maximum capacity. Short-term blinking is not a problem, because the internal limiter 
 
controlls input levels of up to +21dBu down to a THD of approximately 1%. If, on the  
 
other hand, this LED lights constantly, reducing the volume is recommended to 
 
prevent the loudspeaker systems connected from being damaged by probable 
 overload.
Detent potentiometers scaled in dB (steps of 1dB) for 
adjusting the power amp’s overall volume. To prevent 
distortion in mixing consoles connected to your CP-Series 
amp, setting these controls to a value between 0dB and -6dB 
is generally recommended. The dB-scale provides direct 
indication of the control attenuation applied to the fi xed 
internal amplifi cation.
Use the POWER switch, located on the front panel’s, right side to switch the appliance’s power on. The 
soft-start function limits against current inrush peaks on the mains, which in addition prevents the mains 
line protection switch from activating during power-on. The loudspeaker outputs are activated via relay 
switching with a delay of approximately 2 seconds to effi ciently attenuate eventual power-on noise. The 
PROTECT LED lights during the delay time and the fans run at maximum speed. This is normal, con-
fi rming the immaculate operation of the protection circuitry. 