Roper fep310kw Manuel De Montage

Page de 12
7
Power Supply Cord Installation
WARNING: Improper connection of the equipment-grounding 
conductor can result in a risk of electric shock. Check with a 
qualified electrician or service technician if you are in doubt as to 
whether the appliance is properly grounded. Do not modify the 
power supply cord plug. If it will not fit the outlet, have a proper 
outlet installed by a qualified electrician.
This range is manufactured with the neutral terminal connected to 
the cabinet. Use a 3-wire, UL listed, 40- or 50-amp power supply 
cord (pigtail); or if local codes do not permit ground through the 
neutral, use a 4-wire power supply cord rated at 250 volts, 40 or 
50 amps and investigated for use with ranges.
1. Remove the knockout for the 40- or 50-amp power supply 
cord.
2. Assemble a UL listed strain relief in the opening.
3. Insert the power supply cord through the strain relief, allowing 
enough slack to easily attach the wiring to the terminal block.
4. Connect the terminals (ring-type or spade with upturned ends) 
on the end of the power cord to the power supply.
5. Complete electrical connection according to your type 
electrical supply (4-wire or 3-wire electrical connection).
4-wire connection: Power supply cord
Use this method for:
New branch-circuit installations (1996 NEC)
Mobile homes 
Recreational vehicles
In an area where local codes prohibit grounding through the 
neutral
1. Remove the ground-link screw from the range frame. Save the 
ground link screw and cup washer. Bend the ground-link away 
from the range so that it does not contact the range.
2. Connect the green ground wire from the power supply cord to 
the range using the ground-link screw and cup washer. The 
ground wire must be attached first and must not contact any 
other terminal.
3. Use a ¼" nut driver to remove the hex washer head screws 
from the terminal blocks. 
4. Connect the neutral (center) wire to the center terminal 
connector using one of the hex washer head screws. Securely 
tighten screw for proper electrical connection.
5. Connect the other 2 wires (lines 1 and 2) to the outer 
aluminum terminal blocks.
6. Securely tighten screws for proper electrical connection.
7. Tighten strain relief screws.
8. Replace terminal block cover.
9. Plug in range or reconnect power.
3-wire connection: Power supply cord
Use this method only if local codes permit connecting cabinet-
ground conductor to neutral wire of power supply cord.
1. Use a ¼" nut driver and remove the hex washer head screws 
from the aluminum terminal blocks.
A. Remove knockout for 40- or 50-amp power cord 
and UL listed strain relief
A. Ground-link  screw
B. Cup washer
C. Ground-link bent away from range
A
A
C
B
A. Line 1
B. Green ground wire
C. Ground-link screw
D. Hex washer head 
screw
E. Silver-colored terminal 
block screw
F. Ground-link
G. Neutral (center) wire 
H. Line 2
I. UL listed strain relief 
and 40- or 50-amp 
range power supply 
cord
A
B
C
D
E
F
G
H
I