2. Connect the neutral (center) wire to the center terminal 
connector using one of the hex washer head screws. Securely 
tighten screw for proper electrical connection.
3. Connect the other 2 wires (lines 1 and 2) to the outer terminal 
screws on the terminal block.
4. Tighten strain relief screws.
5. Replace terminal block cover.
6. Plug in range or reconnect power.
Direct Wire Installation: Copper or Aluminum Wire
This range may be connected directly to the fuse disconnect or 
circuit breaker box. Depending on your electrical supply, make the 
required 3-wire or 4-wire connection.
1. Remove the knockout as needed for the conduit connection.
2. Assemble a UL listed conduit connector in the opening.
3. Strip outer covering back 3" (7.6 cm) to expose wires. Strip 
the insulation back 1" (2.5 cm) from the end of each wire.
4. Allow enough slack in the wire to easily attach the wiring 
terminal block.
5. Complete electrical connection according to your type 
electrical supply (4-wire or 3-wire electrical connection).
4-wire connection: Direct wire
Use this method for:
New branch-circuit installations (1996 NEC)
Mobile homes 
Recreational vehicles
In an area where local codes prohibit grounding through the 
neutral
1. Remove the ground-link screw from the range frame. Save the 
ground-link screw and cup washer. Bend the ground-link 
away from the range so that it does not contact the range.
2. Connect the bare ground wire to the range using the ground-
link screw and cup washer. The ground wire must be attached 
first and must not contact any other terminal.
A. Line 1
B. Ground-link
C. Hex washer head screw
D. Silver-colored terminal 
block screw
E. Neutral (center) wire
F. Line 2
G. UL listed strain relief 
and 40- or 50-amp range 
power supply cord
A. UL listed conduit connector
A
B
C
D
E
F
G
A
3"
(7.6 cm)
1"
(2.5 cm)
A. Ground-link  screw
B. Cup washer
C. Ground-link bent away from range
A. Bare wire from power 
supply cable
B. Line 1
C. Hex washer head screw
D. Silver-colored terminal 
block screw
E. Line 2
F. Neutral (white) wire
G. UL listed conduit 
connector and power 
supply cable
A
C
B
A
B
C
D
E
F
G