Bosch nem7522uc Manuel De Montage

Page de 20
English 3
*For solid surface countertop installations, use maximum cutout dimensions and 
consult surface manufacturer for specific cutting instructions.
Power Requirements
Power Supply is dual rated: 240 Volts or 208 Volts, 3 wire, 60 Hz, with the follow-
ing circuit breaker requirements: 
Model NEM73: 30 Amp circuit breaker
Model NEM93: 40 Amp circuit breaker
All Models: 240 Volt, 3 Wire, 60 Hz / 208 Volt, 3 Wire, 60 Hz
Connect only to a 3-wire 120/240 or 120/208 volt AC system. The neutral is not 
required for the operation of this appliance but an independent ground is required.
Install a junction box (not supplied), below the counter top within 3 feet (91.4 cm) 
of flexible conduit (supplied) located at the left rear corner of the cooktop rough-in 
box. Plan the installation of the unit so the location of the junction box is within 3 
feet (91.4 cm) of the left rear of the cooktop bottom. It must be accessible from the 
front of the cabinet.
Figure 3 - Junction Box Installation
Table 1: Counter Top Cutout Dimensions
Model
#
Minimum 
Inches / (mm)
Maximum 
Inches / (mm)
NEM73
B
C
19-7/8" / (505 mm)
28-3/4" / (731 mm)
20" / (508 mm)
28-7/8" / (734 mm)
NEM93
B
C
19-7/8" / (505 mm)
34-3/4" / (883 mm)
20" / (508 mm)
34-7/8" / (886 mm)
“j” Box
Conduit
(approx 3 ft.(91.4 cm))
12”
(30.4 cm)  
(approx)