Wolf 700tr Guide De Spécification

Page de 15
ANTI-TIP
BRACKET*
*PLACEMENT OF THE
ANTI-TIP BRACKET
SHOULD BE 24" (610)
FROM THE FRONT OF THE
UNIT WITHOUT PANELS
TO THE BACK OF THE
ANTI-TIP BRACKET.
25" 
(635) 
27" 
(686) 
25" 
(635) 
1
1
/
2
"
(38)
13
1
/
2
"
(343)
TOP VIEW 
SIDE VIEW 
FRONT VIEW 
ANTI-TIP 
BRACKET 
80" 
(2032) 
4
1
/
2
"
(114)
2
1
/
2
"
(64)
15
1
/
2
"
(394)
1
/
4
"
(6) 
13" 
(330) 
ANTI-TIP 
BRACKET 
LOCATE ELECTRICAL WITHIN 
SHADED AREA – ORIENT GROUND 
PRONG TO RIGHT AS SHOWN 
NOTE: ANTI-TIP BRACKET MUST BE INSTALLED TO 
 PREVENT UNIT FROM TIPPING FORWARD 
Planning Information
Integrated Model 700TR
Dimensions in parentheses are in
millimeters unless otherwise specified.
4
I N S T A L L A T I O N S P E C I F I C A T I O N S
D I M E N S I O N S
Finished Rough Opening Width
27" (686)
Finished Rough Opening Height
80" (2032)
Finished Rough Opening Depth
25" (635)*
Location of Electrical
Within shaded area
* The depth of the Model 700TR is 24" (610) from the front of the unit to its back. Your design
may necessitate moving the unit back, or cabinets forward to achieve a flush fit. This will require
a minimum rough opening depth of 25" (635).