Planning Information
Integrated Model 700TR
Dimensions in parentheses are in
millimeters unless otherwise specified.
5
I N S T A L L A T I O N N O T E S
Refer to the illustrations and specifications
for overall dimensions, finished rough opening
dimensions and installation specifics.
IMPORTANT NOTE: The depth of Model 700TR
is 24" (610) from the front of the unit to its
back. Your design may necessitate moving the
unit back, or cabinets forward to achieve a
flush fit. This will require a minimum rough
opening depth of 25" (635). Refer to the instal-
lation illustration on page 4. 
The anti-tip bracket must be installed to
prevent the unit from tipping forward.
Integrated units are compatible with virtually
any style of cabinetry. They can be used with
framed as well as frameless cabinets.
Refer to the full-scale illustrations on pages
14 and 15 for specifics on panels and door
openings.
Door panels can grow beyond 45
3
/
8
"(1153)
and exceed the 80" (2032) height to accommo-
date any size of door as long as you stay below
the recommended door panel weight limit of 
40 lbs (18 kg). Door panels must be a minimum
of 
5
/
8
" (16) thick.
The weight of each drawer panel cannot
exceed 12 lbs (5 kg). Drawer panels must be a
minimum of 
5
/
8
" (16) thick.
For the bottom drawer, the maximum panel
height is 16
11
/
16
" (424). You must keep a
minimum space of 4" (102) clear below the
bottom edge of the lower drawer panel, so the
unit can be properly vented. In addition, any
decorative base molding must be removable for
possible servicing and cleaning of the
condenser.
We recommend using D-style handles, which
should be located on the opposite side from the
hinge, centered on the cabinet door and the
top, center area of the drawer panel.
Two Integrated units may be installed next to
one another. Refer to page 11 for additional
information.
A 115 volt, 6OHz, 15 amp circuit breaker and
electrical supply are required. A separate circuit,
servicing only this appliance is necessary.
All Integrated models are equipped with a
power supply cord with a 3-prong grounding
plug, which must be plugged into a mating
3-prong grounding type wall receptacle. The
electrical outlet must be placed so the ground-
ing prong is to the right of the thinner blades.
The outlet must be flush with the back wall.
Locate electrical within the shaded area shown
in the installation illustration on page 4.
Do not use an extension cord or two prong
adapter. Electrical ground is required on this
appliance. Do not under any circumstances
remove the power supply cord ground prong.
You must follow all National Electrical Code
regulations. In addition, be aware of local codes
and ordinances when installing your service.
The Integrated Refrigeration Installation
Instructions packed with the appliance will give
you step-by-step procedures for making sure
the unit is installed properly.