3com S7906E Guide De Référence
1-11
View
Any view
Default Level
1: Monitor level
Parameters
pse pse-id: Specifies a PSE ID. You can use the display poe device command to view the mapping
between PSE ID and slot.
Description
Use the display poe pse interface command to display the state of all PoE interfaces connected to
the specified PSE.
Examples
# Display the state of all PoE interfaces connected to PSE 7.
<Sysname> display poe pse 7 interface
<Sysname> display poe pse 7 interface
Interface Enable Priority CurPower Operating IEEE Detection
(W) Status class Status
GE2/0/1 enable low 4.4 on 1 delivering-power
GE2/0/2 enable critical 0 power-lack - disabled
GE2/0/3 enable low 0 power-deny - disabled
GE2/0/4 enable critical 0 on - searching
GE2/0/5 enable low 4.0 power-limit 2 delivering-power
GE2/0/6 enable low 0 power-itself - disabled
GE2/0/7 disable low 0 off - fault
GE2/0/8 disable low 0 off - disabled
GE2/0/9 disable low 0 off - disabled
GE2/0/10 disable low 0 off - disabled
GE2/0/11 disable low 0 off - disabled
GE2/0/12 disable low 0 off - disabled
--- 2 port(s) on, 8.4(W) consumed, 171.6(W) Remaining ---
Table 1-7 display poe pse interface command output description
Field
Description
Interface
Shortened form of a PoE interface
Enable
PoE enabled/disabled state. For the value, see
.
Priority
Priority of a PoE interface. For the value, see
.
CurPower
Current power of a PoE interface
Operating
Operating state of a PoE interface. For the value, see
IEEE PD
power
class
Detection
Power detection state of a PoE interface. For the value, see
.