3com S7906E Guide De Référence

Page de 2327
 
1-17 
RRPP configured with ring groups cannot interoperate with RRPP that does not support ring group 
configuration.  
Related commands: domain ringdisplay rrpp ring-group 
Examples 
# Create ring group 1 and enter its view.  
<Sysname> system-view 
[Sysname] rrpp ring-group 1 
[Sysname-rrpp-ring-group1] 
timer 
Syntax 
timer hello-timer hello-value fail-timer fail-value 
undo timer 
View 
RRPP domain view 
Default Level 
2: System level 
Parameters 
hello-value: Hello timer value, in the range 1 to 10 seconds. 
fail-value: Fail timer value, in the range 3 to 30 seconds. 
Description 
Use the timer command to specify the value of the timers of the RRPP domain.  
Use the undo timer command to restore it to the default value. 
By default, the Hello timer value is 1 second and the Fail timer value is 3 seconds. 
Note that the Fail timer value must be greater than or equal to three times of the Hello timer value. 
Examples 
# Set the Hello timer value to 2 seconds and the Fail timer value to 7 seconds. 
<Sysname> system-view 
[Sysname] rrpp domain 1 
[Sysname-rrpp-domain1] timer hello-timer 2 fail-timer 7