3com S7906E Guide De Référence

Page de 2327
 
1-3 
Examples 
# Enable automatic link cost calculation. 
<Sysname> system-view 
[Sysname] isis 
[Sysname-isis-1] auto-cost enable 
bandwidth-reference (IS-IS view) 
Syntax 
bandwidth-reference value 
undo bandwidth-reference 
View 
IS-IS view 
Default Level 
2: System level 
Parameters 
value: Bandwidth reference value in Mbps, ranging from 1 to 2147483648. 
Description 
Use the bandwidth-reference command to set the bandwidth reference value for automatic link cost 
calculation.  
Use the undo bandwidth-reference command to restore the default. 
By default, the bandwidth reference value is 100 Mbps. 
Related commands: auto-cost enable
Examples 
# Configure the bandwidth reference of IS-IS process 1 as 200 Mbps. 
<Sysname> system-view 
[Sysname] isis 
[Sysname-isis-1] bandwidth-reference 200 
circuit-cost 
Syntax 
circuit-cost value [ level-1 | level-2 ] 
undo circuit-cost [ level-1 | level-2 ] 
View 
IS-IS view 
Default Level 
2: System level