3com S7906E Guide D’Installation Rapide
1-25
Table 1-32 Description of LPU status LEDs
LED
Description
RUN
z
ON/OFF: The LPU is faulty or out of position.
z
Blinking: The LPU is operating normally.
ALM
z
OFF: The LPU is operational or out of position.
z
ON: The LPU is faulty.
If the RUN LED flashes at a high frequency, the card is in the startup process, but is not operational yet.
At system startup, the ALM LED will be ON for a while, but it does not mean that the card is faulty.
RESET button
A reset button is provided on the LSQ1CGP24TSC0 for you to reset the card when necessary.
Salience VI-10GE SRPU-LSQ1SRP2XB0
Applicable models
z
S7903E
z
S7906E
z
S7910E
z
S7906E-V
Technical specifications
Table 1-33 Technical specifications of the LSQ1SRP2XB0
Item
Specifications
CPU
MIPS64, 600 MHz
Boot ROM
512 KB
Flash memory
64 MB
DDR SDRAM
512 MB
Dimensions (H × W × D)
45 × 377 × 355 mm (1.77 × 14.84 × 13.98 in.)
Interfaces
z
One CF card interface
z
Two 10GBase-R-XFP Ethernet ports
z
One console port, used for local or remote configuration
and management of the switch through a dialup
connection
and management of the switch through a dialup
connection
z
One 10/100Base-TX management Ethernet port
Power consumption
55 W to 65 W
Panel and LEDs
shows the front panel of the LSQ1SRP2XB0.