ëÉí=äÉÅ=Eã~ñJÅçìåíF
`çãã~åÇ=jçÇÉ
Configuration
aÉëÅêáéíáçå
Set the maximum unknown frame count per time interval for a 
LEC.
* Note:  You must disable a LEC each time you make a change to 
the configuration. After you make configuration 
changes, you must enable the LEC in order for the 
changes to take effect.
póåí~ñ
set lec <lecID> max-count <max-count-value>
q~ÄäÉ=NJORK==m~ê~ãÉíÉêëI=hÉóïçêÇëI=^êÖìãÉåíë
p~ãéäÉ=lìíéìí
This example sets the maximum unknown frame count for LEC 2 to 
15 for a programmed time interval.
ATM(configure)# set lec 2 disable
LEC 2 has been disabled
ATM(configure)# set lec 2 max-count 15
Maximum Unknown Frame Count 15 has been set
for LEC 2
ATM(configure)# set lec 2 enable
LEC 2 has been enabled
Name
Definition
lecID
The LEC identifier. The range of values is: 
Minimum = 1, Maximum = 128.
max-count-value
The maximum unknown frame count.   The 
range of values is: Minimum = 1, Maximum = 
20. The default is 10.