LV-7490  Expand Serial Command Functional Specifications 
                                                                                   
                                                     
23  
 
 
8.5  PC Adjust Control Command 
8.5.1 CF_FSYNC 
Command 
Command “CF_FSYNC_%1”[CR] 
%1 
“0000~0031” --------------- Directly select Fine Sync setting value 
“UP” -------------------------- Current Fine Sync setting value + 1 
“DN” -------------------------- Current Fine Sync setting value - 1 
Details 
Set Fine Sync value of PC signal 
Projector does not save the value set with this command so that it resets when 
projector turning into Standby status or ALL is OFF.   
This command is available in normal Power ON status. 
Response 
Acceptable “000”[CR] 
Unacceptable “Error 
Code”[CR] 
 
8.5.2 CF_TDOTS 
Command 
Command “CF_TDOTS_%1”[CR] 
%1 
“mmmm~nnnn” --- Directly select Total Dots setting value   
“mmmm” shows minimum value, it is current Display Dots Horizontal value + 
Position value
 
“nnnn” shows maximum value, which is not over 140MHz. 
“UP” -------------- Current Total Dots setting value + 1 
“DN” -------------- Current Total Dots setting value - 1 
Details 
Set Total Dots of PC signal 
Projector does not save the value set with this command so that it resets when 
projector turning into Standby status or ALL is OFF.   
This command is available in normal Power ON status. 
Response 
Acceptable “000”[CR] 
Unacceptable “Error 
Code”[CR] 
 
8.5.3 CF_CLAMP 
Command 
Command “CF_CLAMP_%1”[CR] 
%1 
“mmmm~nnnn” ---- Directly select Clamp setting value 
  “mmmm” shows minimum value, fixed-value “0001”. 
  “nnnn” shows maximum value: it depends on input signal. 
“UP” ------------------ Current Clamp setting value + 1 
“DN” ------------------ Current Clamp setting value – 1 
Details 
Set Clamp value of PC signal   
Projector does not save the value set with this command so that it resets when 
projector turning into Standby status or ALL is OFF.   
This command is available in normal Power ON status. 
Response 
Acceptable “000”[CR] 
Unacceptable “Error 
Code”[CR]