Canon LV-7490 Brochure

Page de 74
LV-7490  Expand Serial Command Functional Specifications 
                                                                                   
                                                     
33  
 
 
8.7.7 CF_KEYSTONE 
Command 
Command “CF_KEYSTONE_%1”[CR] 
%1 
“UP” ------------- Correct Keystone distortion to reduce upper part of image 
“FUP” ----------- Correct Keystone distortion to reduce upper part by 2steps 
“DN” ------------- Correct Keystone distortion to reduce lower part of image 
“FDN” ----------- Correct Keystone distortion to reduce lower part by 2steps 
“RST” ------------ Reset Keystone 
Details 
Change Keystone distortion correction 
This command is available in normal Power ON status. 
Response 
Acceptable “000”[CR] 
Unacceptable 
“Error Code”[CR] 
“201”[CR] ----When reaching the Keystone correction limit or  
reaching 1 step to correction limit and “FDN”/”FUP” 
is received. 
                 
(The command is not executed) 
 
8.7.8 CF_KYSTNMODE 
Command 
Command “CF_KYSTNMODE_%1”[CR] 
%1 
“STR” --------- Set Keystone store mode to Store 
“RST” --------- Set Keystone store mode to Reset 
Details 
Set Keystone store mode   
This command is available in normal Power ON status. 
Response 
Acceptable “000”[CR] 
Unacceptable “Error 
Code”[CR] 
 
8.7.9 CF_CEIL 
Command 
Command “CF_CEIL_%1”[CR] 
%1 
“ON” ------------------------ Set Ceiling to ON 
“OFF” ----------------------- Set Ceiling to OFF 
Details 
Set/Cancel Ceiling setting.   
The value set by this command is stored in EEPROM and its setting is effective 
even after ALL is OFF 
This command is available in normal Power ON status. 
Response 
Acceptable “000”[CR] 
Unacceptable “Error 
Code”[CR] 
 
8.7.10  CF_REAR Command 
Command “CF_REAR_%1”[CR] 
%1 
“ON” --------------------------- Set Rear to ON 
“OFF” ------------------------- Set Rear to OFF 
Details 
Set/Cancel Rear setting.   
When Rear is ON, image is left/right reversed. 
The status set by this command is stored in EEPROM and its setting is effective 
after ALL is OFF 
This command is available in normal Power ON status. 
Response 
Acceptable “000”[CR] 
Unacceptable “Error 
Code”[CR]