Canon LV-7490 Brochure

Page de 74
LV-7490  Expand Serial Command Functional Specifications 
                                                                                   
                                                     
35  
 
 
8.9 Sound 
Command 
 
8.9.1 CF_VOLUME 
Command 
Command “CF_VOLUME_%1”[CR] 
%1 
“000-063” -------------------------- Directly select Volume setting value 
“UP” --------------------------------- Current Volume setting value +1 
“DN” --------------------------------- Current Volume setting value -1 
Details 
Control Volume value 
The same operation of Volume Up/Down as projector and RC, and directly select 
Volume setting value. When setting Volume value, the Sound Mute ON status is 
canceled just like RC operation. The value set by this command is stored in 
Projector. 
This command is available in normal Power ON status. 
Response 
Acceptable “000”[CR] 
Unacceptable “Error 
Code”[CR] 
 
8.9.2 CF_MUTE 
Command 
Command “CF_MUTE_%1”[CR] 
%1 
“ON” ----------------------------- Set Sound Mute to ON 
“OFF” --------------------------- Set Sound Mute to OFF 
Details 
Control Sound Mute ON/OFF   
This command is available in normal Power ON status. 
Response 
Acceptable “000”[CR] 
Unacceptable “Error 
Code”[CR] 
 
8.9.3 CF_MIC 
Command 
Command  “CF_MIC_%1”[CR] 
%1 
“ON” ----------------------------- Set MIC to ON 
“OFF” ---------------------------- Set MIC to OFF 
Details 
Control MIC ON/OFF   
This command is available in normal Power ON status. 
Response 
Acceptable “000”[CR] 
Unacceptable “Error 
Code”[CR] 
 
8.9.4 CF_MICGAIN 
Command 
Command “CF_MICGAIN_%1”[CR] 
%1 
“000-063” -------------------------- Directly select MIC gain setting value 
“UP” --------------------------------- Current MIC GAIN setting value +1 
“DN” --------------------------------- Current MIC GAIN setting value -1 
Details 
Control MIC GAIN value 
When setting MIC GAIN value just like operation by menu, the Sound Mute ON 
status is canceled. The value set by this command is stored in Projector. 
This command is available in normal Power ON status.   
Response 
Acceptable “000”[CR] 
Unacceptable “Error 