Canon LV-7490 Brochure

Page de 74
LV-7490  Expand Serial Command Functional Specifications 
                                                                                   
                                                     
61  
 
 
9.9  Lamp Status Read Command 
9.9.1 CR_LAMPREPL 
Command 
Command “CR_LAMPREPL”[CR] 
Details 
Get information of Lamp Replacement time 
Response 
Acceptable “000_%1”[CR] 
%1 
“1Y” -------------------------- Over lamp replacement time 
“1N” -------------------------- Within lamp replacement time 
 
“1” means the number of lamps.   
(1 lamp model→ “1”) 
“Y”/”N” means if it has reached its replacement time or not. 
e.g. “1Y” -----------projector is 1 lamp model and Lamp is over its 
replacement time 
Unacceptable “Error 
Code”[CR] 
 
 
9.9.2 CR_LAMPH 
Command 
Command “CR_LAMPH”[CR] 
Details 
Get total running time of lamp by hour (h) 
*Actual running time, not corresponding value 
Response 
Acceptable “000_%1”[CR] 
%1 “00000”~“99999” 
Unacceptable “Error 
Code”[CR] 
 
 
9.9.3 CR_LAMPCORRESPH 
Command 
Command “CR_LAMPCORRESPH”[CR] 
Details 
Get total running time of lamp by hour (h) 
* Corresponding value, not actual running time   
Response 
Acceptable “000_%1”[CR] 
%1 “00000”~“99999” 
Unacceptable “Error 
Code”[CR] 
 
 
9.9.4 CR_LAMPMODE 
Command 
Command “CR_LAMPMODE”[CR] 
Details 
Get setting status of Lamp Mode 
Response 
Acceptable “000_%1”[CR] 
%1 
“AUTO” -------------------- Lamp Mode is Auto 
“NORMAL” -------------- Lamp Mode is Normal 
“ECO1” --------------------- Lamp Mode is Eco1 
“ECO2” --------------------- Lamp Mode is Eco2 
Unacceptable “Error 
Code”[CR]