Canon LV-7490 Brochure
LV-7490 Expand Serial Command Functional Specifications
61
9.9 Lamp Status Read Command
9.9.1 CR_LAMPREPL
Command
Command “CR_LAMPREPL”[CR]
Details
Get information of Lamp Replacement time
Response
Acceptable “000_%1”[CR]
%1
“1Y” -------------------------- Over lamp replacement time
“1N” -------------------------- Within lamp replacement time
“1” means the number of lamps.
“1N” -------------------------- Within lamp replacement time
“1” means the number of lamps.
(1 lamp model→ “1”)
“Y”/”N” means if it has reached its replacement time or not.
e.g. “1Y” -----------projector is 1 lamp model and Lamp is over its
replacement time
e.g. “1Y” -----------projector is 1 lamp model and Lamp is over its
replacement time
Unacceptable “Error
Code”[CR]
9.9.2 CR_LAMPH
Command
Command “CR_LAMPH”[CR]
Details
Get total running time of lamp by hour (h)
*Actual running time, not corresponding value
*Actual running time, not corresponding value
Response
Acceptable “000_%1”[CR]
%1 “00000”~“99999”
Unacceptable “Error
Code”[CR]
9.9.3 CR_LAMPCORRESPH
Command
Command “CR_LAMPCORRESPH”[CR]
Details
Get total running time of lamp by hour (h)
* Corresponding value, not actual running time
* Corresponding value, not actual running time
Response
Acceptable “000_%1”[CR]
%1 “00000”~“99999”
Unacceptable “Error
Code”[CR]
9.9.4 CR_LAMPMODE
Command
Command “CR_LAMPMODE”[CR]
Details
Get setting status of Lamp Mode
Response
Acceptable “000_%1”[CR]
%1
“AUTO” -------------------- Lamp Mode is Auto
“NORMAL” -------------- Lamp Mode is Normal
“ECO1” --------------------- Lamp Mode is Eco1
“ECO2” --------------------- Lamp Mode is Eco2
“NORMAL” -------------- Lamp Mode is Normal
“ECO1” --------------------- Lamp Mode is Eco1
“ECO2” --------------------- Lamp Mode is Eco2
Unacceptable “Error
Code”[CR]