Canon LV-7490 Brochure
LV-7490 Expand Serial Command Functional Specifications
62
9.9.5 CR_LAMPMSTS
Command
Command “CR_LAMPSTS”[CR]
Details
Get Lighting status of lamp
Response
Acceptable “000_%1”[CR]
%1
“n**** ” A number of * should be among 1-4.
First character shows how many lamps are incorporated in
projector. (1,2 or 4 )
Second character shows following status in order of lamp number.
First character shows how many lamps are incorporated in
projector. (1,2 or 4 )
Second character shows following status in order of lamp number.
“I” Lamp is ON
“O” Lamp is OFF
“X” Lamp failure
“O” Lamp is OFF
“X” Lamp failure
e.g.
“1I” ・・・・・・・ 1 lamp model and Lamp is ON
“2IO・・・・・・・ 2 lamps model and No.1 Lamp is ON and No.2Lamp
“1I” ・・・・・・・ 1 lamp model and Lamp is ON
“2IO・・・・・・・ 2 lamps model and No.1 Lamp is ON and No.2Lamp
is OFF
“4IOXI” ・・・・ 4 lamps model and No.1,No.4 lamps are ON. No.2
lamp is OFF and No.3 model is failed.
Unacceptable “Error
Code”[CR]
9.9.6 CR_PROJH
Command
Command “CR_PROJH”[CR]
Details
Get total running time of Projector by hour (h)
Response
Acceptable “000_%1”[CR]
%1 “0000000”~“0099999”
Unacceptable “Error
Code”[CR]
9.9.7 CR_HMLAMP
Command
Command “CR_HMLAMP”[CR]
Details
Get lamp number.
Response
Acceptable “000_%1”[CR]
%1 “001”
Unacceptable “Error Code” [CR]
9.9.8 CR_
LAMPLIFECONTRL Command
Command “CR_LAMPLIFECONTRL”
[CR]
Details
Get setting status of Lamp life control
Response
Acceptable “000_%1”[CR]
%1
“MODE1” --------------- Lamp life control is Mode1 status
“MODE2” --------------- Lamp life control is Mode2 status
“MODE2” --------------- Lamp life control is Mode2 status
Unacceptable “Error Code” [CR]