Canon CXDI-501G Digital Radiography System Brochure
Superb Digital Radiography with 125 Micron Pixel Pitch in a
Portable Detector with a Detachable Cable
Portable Detector with a Detachable Cable
POWERFUL
The Canon CXDI-501 Series
Digital Radiography (DR) Detectors
offer leading DR technology in a thin,
lightweight and portable flat panel detector.
Designed to fit in most existing Bucky trays, the
CXDI-501 Series DR Detectors, with enhanced
cable routing system, detachable cable, easy-
to-grip handle and 331 lbs (150 kg)
**
of overall
standing pressure, provide the flexibility,
versatility and easy adjustment to aid in the
positioning and everyday workflow of your
system. Help improve performance and
experience added portability with a Canon
CXDI-501 Series DR Detector today.
CANON MEDICAL SYSTEMS
A Division of Canon U.S.A., Inc.
15955 Alton Parkway
Irvine, CA 92618-3731, U.S.A.
Telephone: (U.S.A. only): 800-970-7227, 949-753-4160
Fax: 949-753-4164
Email: drsales@cusa.canon.com
Website: www.usa.canon.com/dr
DRB-018 Rev. A
* Compared to all other Digital Radiography Detectors, except CXDI DR Detectors, as of November 20, 2011.
CANON, CXDI and LANMIT are registered trademarks of Canon Inc. in the United States and may also be
registered trademarks or trademarks of other countries. DICOM is a registered trademark of the National
Electrical Manufacturer’s Association for its standards publications relating to digital communications of
medical information. All other referenced marks are trademarks of their respective owners and are hereby
acknowledged. All rights reserved.
© 2011 Canon U.S.A., Inc
CXDI-501G
(GOS) DR Detector
CXDI-501C
(Csl) DR Detector
CXDI-501 SERIES DR DETECTORS SPECIFICATIONS
IMAGE SIZE
14 x 17
***
INCHES
WEIGHT
6.8
POUNDS
PIXEL PITCH
125
MICRONS
IMAGE PREVIEW
3
SECONDS
*** Image size is an approximate figure
** Up to 221 lbs (100 kg) of overall
standing pressure per 4 cm area
Scintillator
GOS (Gd2O2S: Tb)
Csl (Csl: TI)
Purpose
General Radiography
Method
Flat Panel Detector, Scintillator & Amorphous Silicon (a-Si)
Sensor
LANMIT (Large Area New-MIS Sensor and TFT)
Pixels
2,800 x 3,408 Pixels (9.5 Megapixels)
A/D
14-bit
Grayscale
4,096 grayscale (12-bit)
High Resolution Image
Approx. 5 seconds after X-ray Exposure
Display Time
DICOM
DICOM 3.0 Compatible, Print Management Service Class (SCU), Storage
Service Class (SCU), and Others
Grid Density Required
52 lp/cm
Cycle Time
Approx. 9 sec.
Operating Environment
Sensor Unit: 41 - 95°F (5 - 35°C), 30-80% RH (non-condensing)
Dimensions
18.1 x 16.7 x 0.6 in (460 x 424 x 15 mm)
Sensor Cable Length
21 ft, 4.5 ft + 16.5 ft (7 m, 1.5 + 5.5 m)
Standard Components
Sensor Unit, Power Box, Remote Switch, X-ray Interface Cable
Detector
CXDI-501G
CXDI-501C
Specifications are subject to change without notice.
Lower D ose. Higher Resolution.
*