Superb Digital Radiography with 125 Micron Pixel Pitch in a 
Portable Detector with a Detachable Cable  
POWERFUL
The Canon CXDI-501 Series 
Digital Radiography (DR) Detectors  
offer leading DR technology in a thin, 
lightweight and portable flat panel detector.  
Designed to fit in most existing Bucky trays, the 
CXDI-501 Series DR Detectors, with enhanced 
cable routing system, detachable cable, easy-
to-grip handle and 331 lbs (150 kg)
**
 of overall 
standing pressure, provide the flexibility,  
versatility and easy adjustment to aid in the 
positioning and everyday workflow of your 
system.  Help improve performance and  
experience added portability with a Canon 
CXDI-501 Series DR Detector today.
CANON MEDICAL SYSTEMS
A Division of Canon U.S.A., Inc.
15955 Alton Parkway
Irvine, CA 92618-3731, U.S.A.
Telephone: (U.S.A. only): 800-970-7227, 949-753-4160
Fax: 949-753-4164
Email: drsales@cusa.canon.com
Website: www.usa.canon.com/dr
DRB-018 Rev. A
* Compared to all other Digital Radiography Detectors, except CXDI DR Detectors, as of November 20, 2011. 
CANON, CXDI and LANMIT are registered trademarks of Canon Inc. in the United States and may also be 
registered trademarks or trademarks of other countries. DICOM is a registered trademark of the National 
Electrical Manufacturer’s Association for its standards publications relating to digital communications of 
medical information. All other referenced marks are trademarks of their respective owners and are hereby 
acknowledged.  All rights reserved.
© 2011 Canon U.S.A., Inc
CXDI-501G 
(GOS) DR Detector
CXDI-501C 
(Csl) DR Detector
CXDI-501 SERIES DR DETECTORS SPECIFICATIONS
IMAGE SIZE
     
14 x 17
***
INCHES
WEIGHT 
6.8
POUNDS
PIXEL PITCH 
125
MICRONS
IMAGE PREVIEW 
3
SECONDS
*** Image size is an approximate figure
** Up to 221 lbs (100 kg) of overall  
      standing pressure per 4 cm area
Scintillator 
 
 
                    
GOS (Gd2O2S: Tb)
 
 
 
       
Csl (Csl: TI)
   
 
Purpose  
 
 
General Radiography
Method  
 
 
Flat Panel Detector, Scintillator & Amorphous Silicon (a-Si)
Sensor    
 
 
LANMIT (Large Area New-MIS Sensor and TFT)
Pixels   
 
 
2,800 x 3,408 Pixels (9.5 Megapixels)
A/D 
 
 
 
14-bit
Grayscale 
 
 
4,096 grayscale (12-bit)
High Resolution Image   
Approx. 5 seconds after X-ray Exposure 
Display Time 
 
 
DICOM   
 
 
DICOM 3.0 Compatible, Print Management Service Class (SCU), Storage 
 
 
 
 
Service Class (SCU), and Others
Grid Density Required 
 
52 lp/cm
Cycle Time 
 
 
Approx. 9 sec.
Operating Environment   
Sensor Unit: 41 - 95°F (5 - 35°C), 30-80% RH (non-condensing)
Dimensions 
              
18.1 x 16.7 x 0.6 in (460 x 424 x 15 mm) 
Sensor Cable Length 
 
21 ft, 4.5 ft + 16.5 ft (7 m, 1.5 + 5.5 m)  
 
Standard Components   
Sensor Unit, Power Box, Remote Switch, X-ray Interface Cable
            Detector   
                 CXDI-501G  
 
 
  CXDI-501C
Specifications are subject to change without notice.
Lower D ose.  Higher Resolution.
*