Cisco Cisco IOS Software Release 12.2(10)
14
Open Caveats—Release 12.2(10)DA1
OL-2702-01
Caveats
Open Caveats—Release 12.2(10)DA1
All the caveats listed in
are open in Cisco IOS Release 12.2(10)DA1. This table lists only
severity 1 and 2 caveats and select severity 3 caveats.
Open Caveats—Release 12.2(7)DA
All open caveats in Cisco IOS Release 12.2(7)DA have been resolved.
Table 4
Open Caveats for Cisco IOS Release 12.2(10)DA1
Caveat Number
Description
CSCdx53819
8xDMT cards with interleaving delay configurations of 2000us and below have
problems holding train and/or having less than expected upstream train rates.
problems holding train and/or having less than expected upstream train rates.
Workaround: Avoid interleaving delay values of 2000us and below with
8xDMT cards. Interleaving mode configurations should use 4000us delay or
above. If lower delays are required, Fastpath mode can be used if supported by
CPE being used.
8xDMT cards. Interleaving mode configurations should use 4000us delay or
above. If lower delays are required, Fastpath mode can be used if supported by
CPE being used.
CSCdx57259
The connection between the modem on a 4xDMT line card and the CPE is lost
when an NI-2 redundancy switchover occurs.
when an NI-2 redundancy switchover occurs.
Workaround: None.
CSCdx67720
When you copy a configuration file from a tftp server to the startup_config
through snmp, ccCopyState (CISCO-CONFIG-COPY-MIB) will be in "running"
state ever after. It will not change to "Failed" state.
through snmp, ccCopyState (CISCO-CONFIG-COPY-MIB) will be in "running"
state ever after. It will not change to "Failed" state.
The show startup command displays the following output:
%% Non-volatile configuration memory is being accessed, Try again
Workaround: Make sure that there is enough space available in the nvram before
copying, using snmp or use cli.
copying, using snmp or use cli.
CSCdx84898
Upgrades from Cisco IOS 12.1(7) DA to newer IOS images cause G.SHDSL
ports to occasionally drop and retrain. The error is listed as LOSQ (Loss of Signal
Quality) due to CRC errors detected or LOS when Loss of Frame Sync. is
detected.
ports to occasionally drop and retrain. The error is listed as LOSQ (Loss of Signal
Quality) due to CRC errors detected or LOS when Loss of Frame Sync. is
detected.
Workaround: Newer versions of G.SHDSL firmware have been adjusted to meet
the ratified standards. This may require some fixed-rate loops to not hold train at
the current configured rate used with Cisco IOS 12.1.(7)DA. Reducing the
configured rate in some cases will resolve the issue. Random drops may still
occur on some ports.
the ratified standards. This may require some fixed-rate loops to not hold train at
the current configured rate used with Cisco IOS 12.1.(7)DA. Reducing the
configured rate in some cases will resolve the issue. Random drops may still
occur on some ports.
CSCea56851
3db downstream margin configured ports on 8xDMT do not achieve max
configured downstream rate on loops that should achieve max configured
downstream rate.
configured downstream rate on loops that should achieve max configured
downstream rate.
Workaround: Use of DSL’s recommended 6db downstream margin will achieve
max configured rate on loops expected to achieve max rate.
max configured rate on loops expected to achieve max rate.