Cisco Cisco IOS Software Release 12.2(8)YN

Page de 26
   
11
New Software Features in Release 12.2(8)YN
OL-3406-01 Rev E0
New and Changed Information
Configuring NFAS on PRI Groups
When configuring NFAS, use an extended version of the ISDN pri-group command to specify the 
following values for the associated channelized T1 controllers configured for ISDN:
The range of PRI time slots to be under the control of the D channel (timeslot 24).
The function to be performed by time slot 24 (primary D channel, backup, or none); the latter 
specifies its use as a B channel.
The group identifier number for the interface under this D channel’s control.
To configure ISDN NFAS, complete the following tasks in controller configuration mode:
Note
For additional information about ISDN PRI configuration, refer to the “Configuring ISDN Interfaces for 
Voice” section in the “Configuring the Cisco ICS 7750” chapter of the 
. For detailed ISDN PRI configuration instructions, refer to the “Configuring ISDN 
PRI” chapter in “Part 4, Signaling Configuration” in the 
.
Restrictions
The following restrictions apply when using NFAS on MRPs in the Cisco ICS 7750: 
NFAS is not supported between two MRPs.
MGCP is not supported when using NFAS—you must use H.323 in order to use NFAS.
NFAS must be configured on your service provider’s ISDN switch.
Only the switch types shown in 
 support NFAS.
Command
Purpose
Step 1
pri-group timeslots 1-24 nfas_d primary nfas_int number            
nfas_group number 
Configures, on one channelized T1 controller, the 
NFAS primary D channel.
Step 2
pri-group timeslots 1-24 nfas_d backup nfas_int number            
nfas_group number 
Configures, on a different channelized T1 controller, 
the NFAS backup D channel to be used if the 
primary D channel fails. 
Step 3
pri-group timeslots 1-24 nfas_d none nfas_int number            
nfas_group number
(Optional) Configures, on other channelized T1 
controllers, a 24 B channel interface.
Table 8
ISDN Switch Types and Supported NFAS Types
Switch Type
NFAS Type
AGCS GTD5  
NI-2 NFAS
Lucent 4ESS
Custom NFAS
Lucent 5ESS
NI-2 NFAS
Nortel DMS100
Custom NFAS
Nortel DMS250
Custom NFAS
Other switch types
NI-2 NFAS