Cisco Cisco IOS Software Release 12.2(35)SE

Page de 46
 
19
Release Notes for Catalyst 3750-E and Catalyst 3560-E Switches, Cisco IOS Release 12.2(40)SE
OL-13859-02
Important Notes
When using the logging console global configuration command, low-level messages appear on both 
the stack master and the stack member consoles.
The workaround is to use the logging monitor global configuration command to set the severity 
level to block the low-level messages on the stack member consoles. (CSCsd79037)
In a mixed stack which consists of Catalyst 3750 switches along with Catalyst 3750-E switches, 
when the stack ring is congested with approximately 40 Gb/s of traffic, some of the local traffic from 
one port to another on a Catalyst 3750-E member might be dropped.
The workaround is to avoid traffic congestion on the stack ring. (CSCsd87538)
If a new member switch joins a switch stack within 30 seconds of a command to copy the switch 
configuration to the running configuration of the stack master, the new member might not get the 
latest running configuration and might not operate properly.
The workaround is to reboot the new member switch. Use the remote command all show run 
privileged EXEC command to compare the running configurations of the stack members. 
(CSCsf31301)
When the flash memory of a stack member is almost full, it might take longer to start up than other 
member switches. This might cause that switch to miss the stack-master election window. As a 
result, the switch might fail to become the stack master even though it has the highest priority.
The workaround is to delete files in the flash memory to create more free space. (CSCsg30073)
In a mixed stack of Catalyst 3750 switches and Catalyst 3750-E switches, when the stack reloads, 
the Catalyst 3750-E might not become stack master, even it has a higher switch priority set.
The workaround is to check the flash. If it contains many files, remove the unnecessary ones. Check 
the lost and found directory in flash and if there are many files, delete them. To check the number 
of files use the fsck flash: command. (CSCsi69447)
Device Manager Limitations
This is the device manager limitation:
When you are prompted to accept the security certificate and you click No, you only see a blank 
screen, and the device manager does not launch. 
The workaround is to click Yes when you are prompted to accept the certificate. (CSCef45718)
Important Notes
These sections describe the important notes related to this software release for the Catalyst 3750-E 
and 3560-E switches: