Cisco AsyncOS 9.5 for Email User Guide
 
Chapter 33      System Administration
  Alerts
REPORTING.CLIENT.
JOURNAL.FULL
Reporting Client: The reporting system is unable to maintain 
the rate of data being generated. Any new data generated will 
be lost.
Critical. Sent if the reporting engine is unable to store new 
data.
REPORTING.CLIENT.
JOURNAL.FREE
Reporting Client: The reporting system is now able to handle 
new data.
Information. Sent when the reporting engine is again able to 
store new data.
PERIODIC_REPORTS.
REPORT_TASK.BUILD_
FAILURE
A failure occurred while building periodic report 
‘$report_title’. This subscription has been removed from the 
scheduler. 
report_title’ - the report 
title
Critical. Sent when the reporting engine is unable to build a 
report.
PERIODIC_REPORTS.
REPORT_TASK.EMAIL_
FAILURE
A failure occurred while emailing periodic report 
‘$report_title’. This subscription has been removed from the 
scheduler. 
report_title’ - the report 
title
Critical. Sent when a report could not be emailed.
PERIODIC_REPORTS.
REPORT_TASK.ARCHIVE_FAILURE
A failure occurred while archiving periodic report 
’$report_title’. This subscription has been removed from the 
scheduler. 
report_title’ - the report 
title
Critical. Sent when a report could not be archived.
SENDERBASE.ERROR
Error processing response to query $query: response was 
$response
query’ - The query 
address.
response’ - Raw data of 
response received.
Information. Sent when an error occurred while processing a 
response from SenderBase.
SMTPAUTH.FWD_SERVER_FAILED
_ALERT
SMTP Auth: could not reach forwarding server $ip with 
reason: $why
 ’ip’ - The IP of the remote 
server.
why’ - Why the error 
happened.
Warning. Sent when the SMTP Authentication forwarding 
server is unreachable.
SMTPAUTH.LDAP_QUERY_FAILED
SMTP Auth: LDAP query failed, see LDAP debug logs for 
details.
Warning. Sent when an LDAP query fails.
SYSTEM.HERMES_
SHUTDOWN_FAILURE.
REBOOT
While preparing to ${what}, failed to stop mail server 
gracefully: ${error}$what:=reboot
error’ - The error that 
happened.
Warning. Sent when there was a problem shutting down the 
system on reboot.
SYSTEM.HERMES_
SHUTDOWN_FAILURE.
SHUTDOWN
While preparing to ${what}, failed to stop mail server 
gracefully: ${error}$what:=shut down
error’ - The error that 
happened.
Warning. Sent when there was a problem shutting down the 
system.
Table 33-7
Listing of Possible System Alerts  (continued)
Component/Alert Name
Message and Description
Parameters