Cisco Headend System Release 2.5 Guide De Montage

Page de 51
1-6 
Initial Installation of RNCS Software 
78-4003191-01 Rev B 
Configure the ALOM Port,
 Continued 
 
  5. 
Type setsc  netsc_ipnetmask  [netmask] and then press Enter
Notes:   
• 
Substitute the netmask of the network management port of the Sun Fire 
V240 server for [netmask]. 
• 
The network administrator can help you determine the netmask. 
Result:  This command establishes the netmask of the network 
management port. 
  6. 
Type setsc  netsc_ipgateway [IP address of gateway or router] and then 
press Enter
Notes:   
• 
Substitute the IP address of the gateway or router of the network 
management port of the Sun Fire V240 server for [IP address of gateway 
or router]. 
• 
The network administrator can help you determine the IP address. 
Result:  This command establishes the IP address of the gateway or router 
of the network management port. 
  7. 
Type setsc  sc_powerstatememory  true and then press Enter
Result:  This command sets the sc_powerstatememory variable to true. 
  8. 
Type showsc and then press Enter
Result:  The system displays the value of variables associated with the 
ALOM port. 
  9. 
Is the sc_powerstatememory variable set to true
• 
If yes, type q to exit from the showsc display. 
• 
If no, type q to exit from the showsc display and then repeat this 
procedure from step 7. 
  10.  Type resetsc and then press Enter
Result:  A confirmation message appears. 
  11.  Type y and then press Enter
Result:  After a few messages, the system prompts you to type #. to return 
to the ALOM port. 
  12.  Type #. (Do not press Enter.). 
Result:  The Login prompt appears.