Cisco Headend System Release 2.5 설치 가이드
1-6
Initial Installation of RNCS Software
78-4003191-01 Rev B
Configure the ALOM Port,
Continued
5.
Type setsc netsc_ipnetmask [netmask] and then press Enter.
Notes:
•
Notes:
•
Substitute the netmask of the network management port of the Sun Fire
V240 server for [netmask].
•
The network administrator can help you determine the netmask.
Result: This command establishes the netmask of the network
management port.
6.
Type setsc netsc_ipgateway [IP address of gateway or router] and then
press Enter.
Notes:
•
Notes:
•
Substitute the IP address of the gateway or router of the network
management port of the Sun Fire V240 server for [IP address of gateway
or router].
•
The network administrator can help you determine the IP address.
Result: This command establishes the IP address of the gateway or router
of the network management port.
7.
Type setsc sc_powerstatememory true and then press Enter.
Result: This command sets the sc_powerstatememory variable to true.
Result: This command sets the sc_powerstatememory variable to true.
8.
Type showsc and then press Enter.
Result: The system displays the value of variables associated with the
Result: The system displays the value of variables associated with the
ALOM port.
9.
Is the sc_powerstatememory variable set to true?
•
•
If yes, type q to exit from the showsc display.
•
If no, type q to exit from the showsc display and then repeat this
procedure from step 7.
10. Type resetsc and then press Enter.
Result: A confirmation message appears.
11. Type y and then press Enter.
Result: After a few messages, the system prompts you to type #. to return
to the ALOM port.
12. Type #. (Do not press Enter.).
Result: The Login prompt appears.