Clock Configuration 
 
78-4025112-01 Rev H0 
49 
 
Clock Configuration 
The RF Gateway 1 provides several different configuration options for obtaining and 
maintaining accurate time on the system.  These options include time 
synchronization from a network time server and obtaining time from an on-board 
real-time clock (RTC). 
 
Real -Time Clock Setup 
The RF Gateway 1 has an on-board, real-time clock (RTC) with battery back-up 
which can be used to provide system time. The RTC can be set manually via the web 
interface or configured to be updated with network time obtained from an SNTP 
server.  The Synchronize With Server  parameter is used to control the RTC 
synchronization behavior.  When set to Disabled, the RF Gateway 1 obtains system 
time from the RTC at startup.  Once set, the internal system clock runs 
independently until the RTC is changed. The Clock Configuration page provides the 
following user-configurable options. 
 
Current Time 
 
New Time  
 
Synchronize with Server 
To Set the Real Time Clock: 
1  Navigate to the System/Clock page. 
Result: The Clock Configuration page is displayed. 
 
2  In the New Time field, enter year, date and current time. 
Example: 2008/06/17/0052:26 
3  Click Apply.