Clock Configuration 
 
78-4025112-01 Rev H0 
51 
 
4  In the Backup SNTP Server IP Address field, enter the IP address in xx.xx.xx.xx 
format. 
5  In the SNTP Mode field, select "Unicast" (Multicast is not supported). 
6  In the Time Zone field, select the correct time zone depending on current location. 
7  The Synchronization Interval parameter specifies the interval at which the RF 
Gateway 1 resynchronizes the system clock and RTC to the network time. Set the 
SNTP Synchronization rate in minutes. The default is 1440 minutes or 24 hours. 
8  The Synchronization Timeout parameter specifies how long the RF Gateway waits 
for the network time server to respond. Set the timeout in seconds. 
9  Click Apply.  
10  Click Synchronize Now to force a network synchronization. This sets the 
system's time and RTC. 
11  Click Save
Result: On the next system reboot, the system time is displayed in periodic 
intervals based on the Synchronization Interval setting. 
Parameters 
The following table explains the Clock Configuration parameters. 
Parameter 
Description  
Current Time 
System's current time. 
New Time 
System's new time. 
Synchronize with Server 
Specifies the source of time synchronization, network time server 
or on-board real-time clock. 
Main SNTP Server IP 
Address 
IP address of the Main SNTP server. 
Backup SNTP Server IP 
Address 
IP address of the Backup SNTP server. 
SNTP Mode 
Always set to Unicast. 
Time Zone (Offset from 
UTC) 
Used to configure an offset from UTC time. 
Synchronization Interval 
Specifies the interval at which the system resynchronizes the 
system clock and RTC to the network time. 
Synchronization Timeout  Specifies how long the RF Gateway waits for the network time 
server to respond.  
Last Synchronized Time 
Indicates when the last successful network synchronization 
occurred. 
Additional Configuration 
The RF Gateway 1 provides several additional configuration parameters applicable 
as needed.