Cisco Cisco RF Gateway 1
Clock Configuration
78-4025112-01 Rev H0
51
4 In the Backup SNTP Server IP Address field, enter the IP address in xx.xx.xx.xx
format.
5 In the SNTP Mode field, select "Unicast" (Multicast is not supported).
6 In the Time Zone field, select the correct time zone depending on current location.
7 The Synchronization Interval parameter specifies the interval at which the RF
6 In the Time Zone field, select the correct time zone depending on current location.
7 The Synchronization Interval parameter specifies the interval at which the RF
Gateway 1 resynchronizes the system clock and RTC to the network time. Set the
SNTP Synchronization rate in minutes. The default is 1440 minutes or 24 hours.
SNTP Synchronization rate in minutes. The default is 1440 minutes or 24 hours.
8 The Synchronization Timeout parameter specifies how long the RF Gateway waits
for the network time server to respond. Set the timeout in seconds.
9 Click Apply.
10 Click Synchronize Now to force a network synchronization. This sets the
10 Click Synchronize Now to force a network synchronization. This sets the
system's time and RTC.
11 Click Save.
Result: On the next system reboot, the system time is displayed in periodic
intervals based on the Synchronization Interval setting.
intervals based on the Synchronization Interval setting.
Parameters
The following table explains the Clock Configuration parameters.
Parameter
Description
Current Time
System's current time.
New Time
System's new time.
Synchronize with Server
Specifies the source of time synchronization, network time server
or on-board real-time clock.
or on-board real-time clock.
Main SNTP Server IP
Address
Address
IP address of the Main SNTP server.
Backup SNTP Server IP
Address
Address
IP address of the Backup SNTP server.
SNTP Mode
Always set to Unicast.
Time Zone (Offset from
UTC)
UTC)
Used to configure an offset from UTC time.
Synchronization Interval
Specifies the interval at which the system resynchronizes the
system clock and RTC to the network time.
system clock and RTC to the network time.
Synchronization Timeout Specifies how long the RF Gateway waits for the network time
server to respond.
Last Synchronized Time
Indicates when the last successful network synchronization
occurred.
occurred.
Additional Configuration
The RF Gateway 1 provides several additional configuration parameters applicable
as needed.