ROMMON Release Notes for Cisco RF Gateway 10 With Supervisor Engine RFGW-X4516-10GE
OL-21678-03
Guidelines for Upgrading the ROMMON
Conditions: When the clear config all command is executed, all the environment variables on the
Supervisor are reset, including the SkipDiagsAlways variable, which on power cycle triggers bootup
diagnostics. However, the bootup diagnostics are not supported on the RFGW-10 Supervisor. As a
result the Supervisor hangs at the bootup.
Supervisor are reset, including the SkipDiagsAlways variable, which on power cycle triggers bootup
diagnostics. However, the bootup diagnostics are not supported on the RFGW-10 Supervisor. As a
result the Supervisor hangs at the bootup.
Workaround: In the ROMMON mode, set the variable SkipDiagsAlways to value 1.
Resolved Caveats for Cisco ROMMON Release 12.2(31r)SGA1
•
CSCsz71926
Symptoms: In Stateful Switchover (SSO) mode, the Standby Supervisor boot up is delayed due to a
prolonged bulk configuration synchronization from the Active Supervisor to the Standby
Supervisor. The Standby Supervisor may be reset due to timeout of its boot up process.
prolonged bulk configuration synchronization from the Active Supervisor to the Standby
Supervisor. The Standby Supervisor may be reset due to timeout of its boot up process.
Conditions: This issue occurs when large number of video sessions are configured on the
Cisco RFGW-DS48 line cards on the Cisco RFGW-10 Universal EQAM.
Cisco RFGW-DS48 line cards on the Cisco RFGW-10 Universal EQAM.
Workaround: There is no workaround.
Guidelines for Upgrading the ROMMON
Caution
If your Supervisor engine is shipped with a newer version of ROMMON then do not downgrade! The
new ROMMON will have board settings based on a hardware revision of components, and old settings
will not work.
new ROMMON will have board settings based on a hardware revision of components, and old settings
will not work.
Choosing a ROMMON image for the Supervisor Engine
provides the list of ROMMON software releases supported in various Cisco IOS Releases for
the RFGW-10, along with the ROMMON image filename. To upgrade the Supervisor Engine, download
the appropriate Cisco ROMMON release from Cisco.com using the below information.
the appropriate Cisco ROMMON release from Cisco.com using the below information.