Cisco Prisma HDRx Reverse Optical Receiver Platform & Power Supply System Fiche De Données
Prisma HDRx Reverse Optical Receiver Platform
3
Receiver Specifications, continued
Optical
Units
Notes
Wavelength
nm
1250 to 1600
Optical Input Range:
• HDRx
• HDRx
•
HDRx High Gain
dBm
dBm
dBm
0 to -18
-6 to -18
Optical Input Connector
SC/APC
Optical Test Point
V/mW
1
± 10%, located on network
control module
Optical Status
Red LED fail indicator located on
network control module
RF
Bandwidth
MHz
5 to 65
RF Output Level
See charts on page 2
Output Level Adjustment
Front panel plug in pad
(0 to 20 dB in 0.5 dB steps)
Output Port
75 ohm F-connector on rear panel
of chassis
Return Loss
dB
> 16
Flatness dB
± 0.75 over frequency range
RF test point
-20 dBc F-connector
Unit-to-Unit Isolation
dB
> 65
Redundancy – primary to secondary switch time
ms
< 50
Mechanical
Operating Temperature
°F
°C
+32 to +122
0 to +50
Physical dimensions of chassis
in.
cm
7.0 H x 19.0 W x 10.5 D
17.8 H x 48.3 W x 26.7 D
Weight lb
kg
11.2
5.1
Power Supply Specifications
Modular Primary & 1RU Redundant Power Supplies
Primary Power Supply
(in chassis)
Units
AC
DC
Notes
Power Requirement
V
85 to 264
(50/60 Hz)
-48 2
Power Consumption, fully loaded
W
120
Redundant Power Supply
(1 RU stand-alone)
AC
DC
Power Requirement
V
90 to 264
(50/60 Hz)
-36 to -72
2
Power Consumption, fully loaded
W
220 max.
Physical Dimensions
(excluding mounting brackets)
in.
cm
1.7 H x 17.0 W x 10.0 D
4.3 H x 43.2 W x 25.4 D
4.3 H x 43.2 W x 25.4 D
1
Note:
1.
Mounting brackets fit standard 19-inch and 23-inch racks.
2.
Both DC versions of this power supply are CE compliant.