Cisco Prisma HDRx Reverse Optical Receiver Platform & Power Supply System Data Sheet

Page of 5
Prisma HDRx Reverse Optical Receiver Platform 
 
3
 
 
Receiver Specifications, continued 
 
Optical  
Units 
 
Notes 
Wavelength 
nm 
1250 to 1600 
 
Optical Input Range: 
• HDRx 
• 
HDRx High Gain 
 
dBm 
dBm 
 
0 to -18 
-6 to -18 
 
Optical Input Connector 
 
SC/APC 
 
Optical Test Point 
V/mW 
± 10%, located on network 
control module 
 
Optical Status 
 
Red LED fail indicator located on 
network control module 
 
RF 
 
 
 
Bandwidth 
MHz 
5 to 65 
 
RF Output Level 
 
See charts on page 2 
 
Output Level Adjustment 
 
Front panel plug in pad 
(0 to 20 dB in 0.5 dB steps) 
 
Output Port 
 
75 ohm F-connector on rear panel 
of chassis 
 
Return Loss 
dB 
> 16 
 
Flatness dB 
± 0.75 over frequency range 
 
RF test point 
 
-20 dBc F-connector 
 
Unit-to-Unit Isolation 
dB 
> 65 
 
Redundancy – primary to secondary switch time 
ms 
< 50 
 
Mechanical 
 
 
 
Operating Temperature 
°F 
°C 
+32 to +122 
0 to +50 
 
Physical dimensions of chassis 
in. 
cm 
7.0 H x 19.0 W x 10.5 D 
17.8 H x 48.3 W x 26.7 D 
 
Weight lb 
kg 
11.2 
5.1 
 
 
 
Power Supply Specifications 
 
Modular Primary & 1RU Redundant Power Supplies 
Primary Power Supply 
(in chassis)
 
Units 
AC 
DC 
Notes 
Power Requirement 
85 to 264 
(50/60 Hz) 
-48 2 
Power Consumption, fully loaded 
120 
 
Redundant Power Supply 
(1 RU stand-alone)
 
 
AC 
DC 
 
Power Requirement 
90 to 264 
(50/60 Hz) 
-36 to -72 
Power Consumption, fully loaded 
220 max. 
 
Physical Dimensions 
(excluding mounting brackets) 
in. 
cm 
1.7 H x 17.0 W x 10.0 D 
4.3 H x 43.2 W x 25.4 D 
Note: 
1. 
Mounting brackets fit standard 19-inch and 23-inch racks. 
2. 
Both DC versions of this power supply are CE compliant.