Akai mpc3000 Manuel D’Utilisation

Page de 276
Page 213
Chapter 11: MIDI Function
MIDI Input Filter
Selecting option 3 from the MIDI key menu presents the MIDI
Input Filter screen, which allows specific types of MIDI events to be
either received or ignored by the MPC3000:
===== Sound Generator Input Filter =====
MIDI volume:RECEIVE     MIDI vol now:127
Prog change:IGNORE
======= Sequencer Input Filter =========
Event:NOTES
Pass event?:YES         Min change:5
Velocity mode:NORMAL    Fixed veloc: 64
========================================
There are two sections, the Sound Generator Input Filter and the
Sequencer Input Filter. The fields are:
The Sound Generator Input Filter section:
• The 
MIDI volume
 field:
This choice field has two options: 
RECEIVE
 and 
IGNORE
. If set to
RECEIVE
, incoming MIDI volume messages (controller 7) will
affect the sound generator’s overall output volume on all outputs. If
set to 
IGNORE
, incoming MIDI volume messages will be ignored.
• The 
MIDI vol now
 field:
This field shows the last value of MIDI volume (controller 7)
received. A value of 127 is normal (no attenuation). Any value less
than 127 causes the volume of all outputs to be attenuated from
normal. A VALUE OF ZERO WILL SILENCE ALL AUDIO
OUTPUTS EVEN IF ALL OTHER PARAMETERS ARE SET
CORRECTLY!
• The 
Prog change
 field:
This choice field has two options: 
RECEIVE
 and 
IGNORE
. If set to
RECEIVE
, incoming Program Change messages will automatically
select the active program. (Incoming Program Change messages
above program 24 will select program 24.) If set to 
IGNORE
, incom-
ing Program Change messages will be ignored.
The Sequencer Input Filter section:
• The 
Event
 and 
Pass event?
 fields:
The 
Event
 field is a choice field and can be set to any one of the
following event types: