3com link 1000 Manuel D’Utilisation

Page de 152
Unit Overview — Front
1-11
10BASE-T Ports
The Switch has 12 or 24 10BASE-T RJ45 ports con-
figured as MDIX (cross-over), which provide a full 
10Mbps bandwidth to attached endstations. The 
maximum segment length is 100m (328ft) over cat-
egory 3, 4, or 5 UTP cable.
As these ports are configured as MDIX (cross-over), 
you need to use a cross-over cable to connect to 
devices whose ports are MDIX-only. Most of the 
10BASE-T ports in 3Com devices are MDIX-only.
100BASE-TX Port
The Switch has a single Fast Ethernet 100BASE-TX 
RJ45 port configured as MDIX (cross-over), which 
provides a 100Mbps connection to, for example, a 
local server. The maximum segment length is 100m 
(328ft) over category 5 UTP or STP cable.
As this port is configured as MDIX (cross-over), you 
need to use a cross-over cable to connect to devices 
whose ports are MDIX-only. Most of the 
100BASE-TX ports in 3Com devices are MDIX-only.
LEDs
The table below describes the LED behavior on the 
Switch. For more details about corrective action in 
the event of a problem, refer to 
 on 
.
LED
Color
Indicates
TCVR
Yellow
Port 1 is a Transceiver Module fitted to the 
rear of the unit.
Port Status LEDs
Packet
Yellow
Frames are being transmitted/received on the 
port.
Status
Green
Link is present; port is enabled.
Green flashing
Link is present; port is disabled.
Off
Link is not present.
Plug-in Module Status LEDs
Packet
Yellow
Frames are being transmitted/received on the 
Plug-in Module port.
Status
Green
Link is present; port is enabled.
Green flashing
Link is present; port is disabled.
Green flashing
(long on, short 
off)
Refer to the “SuperStack II Switch ATM 
OC-3c Module User Guide”
.
Yellow
Plug-in Module has failed its Power On Self 
Test (if the MGMT LED is flashing yellow), or 
the agent software of the Plug-in Module is 
not installed correctly.
Yellow flashing
Plug-in Module is not recognized.
Off
Link is not present or Plug-in Module is not 
installed in the Switch.
Unit Status LEDs
Power
Green
Switch is powered-up.
MGMT
Green
Switch is operating normally.
Green flashing
Switch or Plug-in Module is either down-
loading software or initializing (which 
includes a Power On Self Test).
Yellow
Switch has failed its Power On Self Test.
Yellow flashing
Plug-in Module has failed its Power On Self 
Test.