ADC H2TU-C-231 Manuel D’Utilisation

Page de 74
Front Panel
LTPH-UM-1109-01, Issue 1
6
January 9, 2002
H2TU-C-231 List 2
NREM
Network Remote Loopback
DSX-1 signal is looped back to the network at the H2TU-R.
RULB
Remote Unit Loopback
Dual loopback at the H2TU-R.
SMJK
Remote SmartJack Loopback
DSX-1 signal is looped back to the network at the H2TU-R SmartJack module.
DIAGNOSTIC MESSAGES
A = xx
Maximum Loop Attenuation
The Attenuation (A) message appears followed by xx, where xx is the 
highest loop attenuation measured in dB.
ACQ
Acquisition
The multiplexers of the H2TU-C and H2TU-R are trying to establish 
synchronization over the HDSL2 loop.
ARM
HiGain System Armed
Armed to respond to Intelligent Repeater Loop (ILR) codes.
BAD RT?
No Response from H2TU-R
The H2TU-C does not receive any response from the H2TU-R and all 
HDSL2 loop conditions are normal. Therefore, the integrity of the H2TU-R 
or the HDSL2 loop is questionable.
FERR
Framing Bit Error Occurred
Framing bit error occurred at H2TU-C DSX-1 input.
FLDL
Flash Download
Flash download of firmware upgrades. Contact Customer Service for 
upgrades procedures (see 
).
HES
HDSL2 CRC Error
H2TU-C HDSL2 Loop Cyclical Redundancy Check (CRC) error.
LBPV
Local Bipolar Violation
A bipolar violation has been received at the DSX-1 input to the 
H2TU-C-231.
M=xx 
HDSL2 Loop Margin
Indicates the power of the received HDSL2 signal relative to noise (S/N 
with respect to 21.5 dB). Any value of 6 dB or greater is adequate for 
reliable system operation.
MNGD
Managed
The H2TU-C-231 is under control of the HMU-319 network management 
unit. In this state, the front-panel craft port and pushbuttons are disabled.
PWR FEED OFF 
Power Feed Off
HDSL2 span power has been turned off by setting the PWRF option to off, 
or HDSL2 span power has been turned off by use of the A1LB, A2LB, or 
A5LB Intelligent Office Repeater (IOR) Power Down code.
PWR FEED ON
Power Feed On
Indicates that the HDSL2 loop is not grounded or shorted.
SIG
Signaling
The transceivers of the H2TU-C and H2TU-R are trying to establish contact 
with each other over the HDSL2 loop.
SYSTEM INFORMATION MESSAGES
 (a)
 
CODE xxxx
Line Code: AMI or B8ZS
The line code that H2TU-C-231 is receiving at its DSX-1 interface, if the 
DS1 option is set to AUTO. Otherwise, it mimics either of the other two 
DS1 line code settings, Alternate Mark Inversion (AMI) or Bipolar with 
8-Zero Substitution (B8ZS). 
FRM xxxx
Frame: SF, ESF, UNFR
Defines the type of frame pattern being received from the DSX-1: 
SuperFrame (SF), Extended SuperFrame (ESF), or Unframed (UNFR). 
LATT xx
Loop Attenuation
Current loop attenuation threshold setting is measured in dB.
LIST xx
List Number
List number of the H2TU-C-231.
MARG xx
Margin 
Current margin threshold setting is measured in dB.
VER x.xx
Software Version Number
Software version number of the H2TU-C-231.
(a) System information messages are displayed in scroll mode. To scroll through the messages, press the MODE pushbutton for
3 or more seconds.
Table 2.
Front-Panel Display Messages (Continued)
Message
Full Name
Description