ADC H2TU-C-231 Manuel D’Utilisation

Page de 74
LTPH-UM-1109-01, Issue 1
Front Panel
H2TU-C-231 List 2
January 9, 2002
5
lists the front-panel display messages. The four-character display reports the code of a pertinent alarm,
loopback, or diagnostic message and, in some cases, is followed by a second four-character message that modifies
the first message with a value or current configuration setting.
Table 2.
Front-Panel Display Messages
Message
Full Name
Description
SYSTEM ALARM MESSAGES
ACO
Alarm Cutoff 
A system alarm has occurred and has been retired to an ACO condition by 
pressing the SEL pushbutton on the H2TU-C front panel.
ALRM
Alarm Condition Exists
A system alarm condition is in effect.
DBER
DS1 Bit Error Rate
A system DS1 BER alarm is in effect and remains in effect until cleared.
HBER
HDSL2 Block Error Rate
A system HDSL2 Block Error Rate alarm is in effect.
LA
Loop Attenuation
Indicates that the attenuation on the HDSL2 loop has exceeded the 
maximum threshold value.
LAIS
Line Alarm Indication Signal
Indicates an AIS (unframed all ones) pattern, is being received or 
transmitted at the H2TU-C DS1 input or output ports.
LLOS
Line (Unit) Loss of Signal
Indicates that no signal is detected at the DSX-1 input to the H2TU-C. 
Causes a system alarm.
LOSW
Loss of Sync Word
Indicates that the HDSL2 loop has lost synchronization. 
LRAI
Line RAI
Indicates an RAI alarm (yellow) from the CPE with an error-free signal 
from the line unit or network. RAI signal is transmitted towards the 
network.
MAL
Margin Alarm
The margin on HDSL2 loop has dropped below the threshold 
(0 to 15 dB) as set by the operator.
PWR FEED GND
Ground 
The HDSL2 loop is grounded.
PWR FEED OPEN Open
Indicates a line power open condition.
PWR FEED SHRT
Short
Indicates a short between the Tip and Ring of the HDSL2 pair.
PRMF
Performance Report Messaging - 
Far End
H2TU-R PRM-FE BER threshold has been exceeded.
PRMN
Performance Report Messaging - 
Near End
H2TU-R PRM-NE BER threshold has been exceeded.
RAIS
Remote Alarm Indication Signal
Indicates an AIS an (unframed all ones) pattern is being received at the 
H2TU-R DS1 input port.
RLOS
Remote (Unit) Loss of Signal
Indicates that no signal is detected at the DS1 input to the H2TU-R. Causes 
a system alarm.
RRAI
Remote RAI
Indicates an RAI alarm (yellow) from the CPE with errors from the line unit 
or network.
TUC
Transmission Unit Central Office
Accompanies the HBER, MAL, and LA alarm and indicates that the alarm 
has occurred at the H2TU-C central office unit.
TUR
Transmission Unit Remote End
Accompanies the HBER, MAL, and LA alarm and indicates that the alarm 
has occurred at the H2TU-R remote unit.
LOOPBACK MESSAGES
CLOC
Customer Local Loopback
Signal from customer is looped back to the customer at the H2TU-R.
COLB
Central Office Loopback
Dual loopback at the H2TU-C.
CREM
Customer Remote Loopback
Signal from customer is looped back to the customer at H2TU-C-231.
NLOC
Network Local Loopback
DSX-1 signal is looped back to the network at the H2TU-C.
Continued