 EDU-409 List 1
D
OUBLER
 E
NCLOSURE
 C
APACITIES
 
WITH
 F
ULL
 
S
OLAR
 L
OAD
The EDU-409 List 1 can be housed in a variety of outdoor enclosures 
manufactured by ADC and other vendors. The number of doublers used in 
any of the enclosures depends on the maximum outside ambient temperature. 
The doubler capacities for several of these standard enclosures is listed in 
 and 
. The capacities listed in 
 
(for both indoor and outdoor enclosures) are based on a maximum outside 
temperature of +46.1 °C (+115 °F). Consult ADC for the latest deployment 
rules when using the enclosures at ambient temperatures above +46.1 °C. 
These requirements comply with Bellcore standards, which 
require HDSL equipment place in outdoor cabinets to operate 
in a temperature, outside the housing, of -40 °F (-40 °C) with 
no solar load and +115 °F (+46.1 °C) with a maximum solar 
load and maximum power dissipation. 
Full solar load is equal to maximum sunlight exposure as 
defined in Bellcore’s Technical Advisory TR-TSY-000057.